Parameters
Parameter List
FR-A800
5 - 29
PI
D c
o
ntr
o
l
1134
A605
PID upper limit manipulated value
0 to 100%
0.1%
100%
1135
A606
PID lower limit manipulated value
0 to 100%
0.1%
100%
1136
A670
Second PID display bias coefficient
0 to 500, 9999
0.01
9999
1137
A671
Second PID display bias analog value
0 to 300%
0.1%
20%
1138
A672
Second PID display gain coefficient
0 to 500, 9999
0.01
9999
1139
A673
Second PID display gain analog value
0 to 300%
0.1%
100%
1140
A664
Second PID set point/deviation input
selection
1 to 5
1
2
1141
A665
Second PID measured value input
selection
1 to 5
1
3
1142
A640
Second PID unit selection
0 to 43, 9999
1
9999
1143
A641
Second PID upper limit
0 to 100%, 9999
0.1%
9999
1144
A642
Second PID lower limit
0 to 100%, 9999
0.1%
9999
1145
A643
Second PID deviation limit
0 to 100%, 9999
0.1%
9999
1146
A644
Second PID signal operation selection
0 to 3, 10 to 13
1
0
1147
A661
Second output interruption detection
time
0 to 3600 s, 9999
0.1 s
1
1148
A662
Second output interruption detection
level
0 to 590 Hz
0.01 Hz
0 Hz
1149
A663
Second output interruption cancel level
900 to 1100%
0.1%
1000%
PL
C
func
tion
1150 to
1199
A810 to
A859
PLC function user parameters 1 to 50
0 to 65535
1
0
⎯
1220
B100
Target position/speed selection
0 to 2
1
0
Simpl
e
position c
o
ntr
o
l
1221
B101
Start command edge detection
selection
0, 1
1
0
1222
B120
First positioning acceleration time
0.01 to 360 s
0.01 s
5 s
1223
B121
First positioning deceleration time
0.01 to 360 s
0.01 s
5 s
1224
B122
First positioning dwell time
0 to 20000 ms
1 ms
0 ms
1225
B123
First positioning sub-function
0, 1, 10, 11, 100, 101, 110,
111
1
10
1226
B124
Second positioning acceleration time
0.01 to 360 s
0.01 s
5 s
1227
B125
Second positioning deceleration time
0.01 to 360 s
0.01 s
5 s
1228
B126
Second positioning dwell time
0 to 20000 ms
1 ms
0 ms
1229
B127
Second positioning sub-function
0, 1, 10, 11, 100, 101, 110,
111
1
10
1230
B128
Third positioning acceleration time
0.01 to 360 s
0.01 s
5 s
1231
B129
Third positioning deceleration time
0.01 to 360 s
0.01 s
5 s
1232
B130
Third positioning dwell time
0 to 20000 ms
1 ms
0 ms
1233
B131
Third positioning sub-function
0, 1, 10, 11, 100, 101, 110,
111
1
10
1234
B132
Fourth positioning acceleration time
0.01 to 360 s
0.01 s
5 s
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (28)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......