Parameters
(A) Application parameters
FR-A800
5 - 593
Selection of trace mode (Pr. 1021)
●
Select how to save the trace data which results from sampling the inverter status.
●
There are two trace data save methods, memory mode and recorder mode.
Setting of sampling cycle (interval) and number of sampling channels (Pr. 1022, Pr. 1023)
●
Set the sampling cycle (interval).
The shortest cycle in the recorder mode is 1 ms. When the recorder mode is set, sampling is
performed at a sampling cycle of 1 ms even if "0, 1" is set to Pr. 1022 "Sampling cycle".
●
When the memory mode is set, the number of analog channels to sample can be set in the Pr.
1023 "Number of analog channels". Start setting from the smaller channel number. Up to eight
channels can be set. The sampling time becomes shorter the more channels are set.
The number of channels is always 8 when the recorder mode is used or when digital channels are
used.
●
The sampling time differs according to the sampling cycle and number of sampling channels.
Pr. 1021
setting
Mode
Description
0
Memory
mode
In this mode, trace data is saved sequentially to internal RAM on the inverter.
If automatic transfer is set, the trace data in internal RAM is transferred to USB memory device
when the trigger is being generated.
Data can be transferred to a USB memory device as long as data is held in internal RAM.
Trace data in internal RAM is cleared when the power supply is turned OFF or when the inverter
is reset.
1
Memory
mode
(automatic
transfer)
2
Recorder
mode
In this mode, trace data is saved directly to USB memory device.
Sampling data is fixed at eight analog channels and eight digital channels.
The sampling cycle in this mode is longer than in the memory mode. (1 ms or longer)
Tab. 5-254:
Selection of trace mode
NOTES
When the trace function is used in the recorder mode, use a USB memory device having at least
1 GB of free space.
Data transferred to USB is saved in the "TRC" folder under the "FR_INV" folder.
Up to 99 sets of trace data can be saved in the USB memory device. When data transfer to USB
memory device reaches 99 sets of trace data, data is successively overwritten starting with the
older data.
Number of channels
Memory mode sampling time
Minimum (Pr. 1022 = "0")
Maximum (Pr. 1022 = "9")
1
213 ms
1704 s
2
160 ms
1280 s
3
128 ms
1024 s
4
106.5 ms
852 s
5
91.8 ms
728 s
6
80.0 ms
640 s
7
71.8 ms
568 s
8
60 ms
512 s
Tab. 5-255:
Memory mode sampling time
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......