Outline dimension drawings
Specifications
8 - 22
Dimensions table
NOTE
Make sure to earth the earth terminal of the frame installation foot as well as the earth terminal in
the terminal box.
SF-V5RU
첸
K
1
2
3
5
7
11
15
18
22
—
30
37, 45
55
SF-V5RU
첸
K1
—
1
2
3
5
7
11
—
15
18
—
22, 30
37
SF-V5RU
첸
K3
—
—
1
2
3
5
7
—
11
15
—
18, 22
30
SF-V5RU
첸
K4
—
—
—
—
1
2
3
—
—
5
7
—
11, 15
Frame No.
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225S
Mass [kg]
24
33
41
52
62
99
113
138
160
200
238
255
320
Motor
A
256.5
284
278
303
322
412
434
438.5
457.5
483.5
500
B
114
128
135
152
171
198
220
225.5
242.5
267.5
277
C
90
100
112
132
132
160
160
180
180
200
225
D
183.6
207
228
266
266
318
318
363
363
406
446
E
70
80
95
108
108
127
127
139.5
139.5
159
178
F
62.5
70
70
70
89
105
127
120.5
139.5
152.5
143
H
198
203.5
226
265
265
316
316
359
359
401
446
I
—
230
253
288
288
367
367
410
410
—
—
KA
53
65
69
75
94
105
127
127
146
145
145
KG
65
78
93
117
117
115
115
139
139
487
533
KL(KP)
220
(210)
231
242
256
256
330
330
352
352
(546)
(592)
L
425
477
478
542
580
735
779
790
828
909
932
M
175
200
230
256
256
310
310
335
335
390
428
ML
—
212
242
268
268
—
—
—
—
—
—
N
150
180
180
180
218
254
298
285
323
361
342
XB
56
63
70
89
89
108
108
121
121
133
149
Q
—
60
60
80
80
—
—
—
—
—
—
QK
—
45
45
63
63
—
—
—
—
—
—
R
168.5
193
200
239
258
323
345
351.5
370.5
425.5
432
S
24j6
28j6
28j6
38k6
38k6
42k6
42k6
48k6
55m6
60m6
65m6
T
7
7
7
8
8
8
8
9
10
11
11
U
4
4
4
5
5
5
5
5.5
6
7
7
W
8
8
8
10
10
12
12
14
16
18
18
Terminal
screw
size
U, V, W
M6
M6
M6
M6
M6
M8
M8
M8
M8
M10
M10
A, B, (C)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
G1, G2
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
Tab. 8-11:
Dimensions table (Unit: mm)
NOTES
Install the motor on the floor and use it with the shaft horizontal.
Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
The size difference of top and bottom of the shaft center height is
The 400 V class motor has -H at the end of its type name.
0
-0.5
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......