Parameters
Speed control under Real sensorless vector control, vector control, PM sensorless vector control
FR-A800
5 - 107
5.3.6
Troubleshooting in the speed control
No. Condition
Cause
Countermeasure
1
The motor does not
rotate.
(Vector control)
Motor wiring is incorrect.
앫
Check the wiring.
Set V/F control (set Pr. 80 "Motor capacity" or Pr. 81 "Number of
motor poles" to "9999") and check the motor rotation direction.
For SF-V5RU (1500 r/min series), set Pr. 19 "Base frequency
voltage" to "170 V (340 V)" when the value is 3.7 kW or lower,
and set it to "160 V (320 V)" when the value is higher, and set
Pr. 3 "Base frequency" to "50 Hz".
When a forward signal is input, rotation in the
counterclockwise direction as viewed from the
motor shaft direction is correct. (Clockwise
rotation means that the phase sequence of the
inverter secondary side wiring is different.)
Encoder type selection
switch (Vector control
compatible option) is
incorrect.
앫
Check the encoder specifications.
Check the encoder type selection switch of differential/
complementary (Vector control compatible option).
Wiring of encoder is
incorrect.
앫
When using the system where the motor shaft can be rotated
by an external force other than the motor without any safety
troubles, rotate the motor counterclockwise and check if FWD is
indicated.
If REV is indicated, the phase sequence of the encoder is
incorrect.
Check the wiring, and set Pr. 359 (Pr.852)"Encoder rotation
direction" in accordance with the motor specification.
(Refer to page 2-61.)
If the clockwise direction is forward as viewed from the motor
shaft side, set Pr. 359 (Pr.852)= "0".
If the counterclockwise direction is forward as viewed from the
motor shaft side, set Pr. 359 (Pr.852)= "1".
The parameter setting
and the number of
encoder pulses used are
different.
앫
If the parameter setting value is lower than the number of
encoder pulses used, the motor will not rotate. Set Pr. 369 (Pr.
851) "Number of encoder pulses" correctly.
Encoder power
specifications are
incorrect. Alternatively,
power is not input.
앫
Check the encoder power specifications (5 V/12 V/15 V/24 V),
and input the external power supply. When the encoder output
is the differential line driver type, only 5 V can be input. Make
the voltage of the external power supply the same as the
encoder output voltage, and connect the external power
supply between PG and SD.
The option to be used
and parameter settings
do not match.
앫
Correctly set Pr. 862 "Encoder option selection" according to
the option to be used. (Refer to page 5-64.)
2
Motor does not run
at the correct
speed.
(Command speed
and actual speed
differ.)
Speed command from
the controller is different
from the actual speed.
The speed command is
affected by noise.
앫
Check that the speed command sent from the controller is
correct. (Take EMC measures.)
앫
Set Pr. 72 "PWM frequency selection" lower.
The command speed
and the speed
recognized by the
inverter are different.
앫
Adjust the bias and gain (Pr. 125, Pr. 126, C2 to C7, C12 to C15)
of the speed command again.
The setting for the
number of encoder
pulses is incorrect.
앫
Check the setting of Pr. 369 (Pr. 851)"Number of encoder pulses"
(vector control). (Refer to page 2-73.)
3
The speed does not
accelerate to the
command speed.
Torque shortage.
The torque limit is
operating.
앫
Raise the torque limit.
(Refer to the torque limit for speed control on page 5-84.)
앫
Increase the capacity.
Only P (proportional)
control is performed.
앫
Speed deviation occurs under P (proportional) control when
the load is heavy. Select PI control.
Tab. 5-39:
Troubleshooting (1)
Sensorless
Sensorless
Sensorless Vector
Vector
Vector
PM
PM
PM
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......