Parameters
(D) Operation command and frequency command
FR-A800
5 - 277
Follows the Pr. 338 "Communication operation command source" and Pr. 339 "Communication
speed command source" settings. (Refer to page 5-274.)
At occurrence of RS-485 communication error, the inverter cannot be reset from the computer.
PU stop is only enabled. PS is displayed on the operation panel during PU stop. Follows the Pr. 75
"Reset selection/disconnected PU detection/PU stop selection" setting. (Refer to page 5-192.)
#
Writing of some parameters may be disabled by the Pr. 77 "Parameter write selection" setting and
the operating condition. (Refer to page 5-203.)
,
Some parameters are write-enabled independently of the operation mode and command source
presence/absence. Writing is also enabled when Pr. 77 = "2". (Refer to page 5-203.) Parameter clear
is disabled.
$
When Pr. 550 "NET mode operation command source selection" = "1" (RS-485 terminals enabled),
or Pr. 550 "NET mode operation command source selection" = "9999" with no communication
option connected.
%
When Pr. 550 "NET mode operation command source selection" = "0" (communication option
enabled), or Pr. 550 "NET mode operation command source selection" = "9999" with communica-
tion option connected.
Control via USB
connector
3
(USB connector)
9999
(automatic
recognition, with
USB connection)
Operation
command
(start, stop)
×
×
×
Running frequency
×
×
×
Monitor
Parameter writing
Parameter read
Inverter reset
Other than the
above
Operation
command
(start, stop)
×
×
×
×
×
Running frequency
×
×
×
×
×
Monitor
Parameter writing
Parameter read
Inverter reset
Communica-
tion option (via
communica-
tion)
⎯
Operation
command
(start, stop)
×
×
×
×
×
Running frequency
×
×
×
×
×
Monitor
Parameter writing
Parameter read
Inverter reset
×
×
×
×
×
External
terminal at the
control circuit
⎯
Inverter reset
Operation
command
(start, stop)
×
×
Frequency setting
×
×
: Valid, ×: Invalid, Δ: Partially valid
Command
source
Condition
(Pr. 551 setting)
Item
Controllability in each operation mode
PU
operation
External
operation
External/PU
combined
operation
mode 1
(Pr. 79 =3)
External/PU
combined
operation
mode 2
(Pr. 79 =4)
NET
operation
(when RS-485
terminals are
used)
$
NET
operation
(when
communica-
tion option is
used)
%
Tab. 5-109:
Functions in the single operation modes (2)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......