Protective functions
Causes and corrective actions
FR-A800
6 - 31
Operation panel
indication
E.SAF
FR-LU-08
Safety circuit fault
Name
Safety circuit fault
Description
앫
The inverter trips when a safety circuit fault occurs.
앫
The inverter trips if the either of the wire between S1 and SIC or S2 and SIC becomes non-
conductive while using the safety stop function.
앫
When not using the safety stop function, the inverter trips when the shorting wire between
terminals S1 and PC or across S2 and PC is disconnected.
Check point
앫
Check that the safety relay module or the connection has no fault when using the safety
stop function.
앫
Check if the shorting wire between S1 and PC or between S2 and PC is disconnected when
not using the safety stop function.
Corrective action
앫
When using the safety stop function, check that wiring of terminal S1, S2 and SIC is correct
and the safety stop input signal source such as a safety relay module is operating properly.
Refer to the Safety stop function instruction manual for causes and countermeasures.
(Please contact your sales representative for the manual.)
앫
When not using the safety stop function, short across terminals S1 and PC and across S2 and
PC with shorting wires. (Refer to page 2-54.)
Operation panel
indication
E.PBT
FR-LU-08
PBT fault
E.13
Intrnl circuit fault
Name
Internal circuit fault
Description
The inverter trips when an internal circuit fault occurs.
Corrective action
Please contact your sales representative.
Operation panel
indication
E.OS
FR-LU-08
Overspeed
occurrence
Name
Overspeed occurrence
Description
The inverter trips when the motor speed exceeds the Pr. 374 "Overspeed detection level" under
encoder feedback control, Real sensorless vector control, vector control, and PM sensorless
vector control. This protective function is not available in the initial status.
Check point
앫
Check that the Pr. 374 setting is correct.
앫
Check that the number of encoder pulses does not differ from the actual number of Pr.
369(Pr. 851) "Number of encoder pulses" (under encoder feedback control or vector control).
Corrective action
앫
Set the Pr. 374 correctly.
앫
Set the Pr 369 (851) correctly (under encoder feedback control or vector control).
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......