Parameters
Torque control under Real sensorless vector control and vector control
FR-A800
5 - 141
Speed limit mode 3 (Pr. 1113 = "1")
●
Select this mode when the torque command is positive. The forward rotation command is for
power driving (such as winding) and the reverse rotation command is for regenerative driving
(such as unwinding). (Refer to each inside of the frames in the following figures.)
●
When Pr. 807 "Speed limit selection" = "0 or 2", the speed setting value for speed control is applied
for the speed limit. When Pr. 807 "Speed limit selection" = "1", the setting of Pr. 808 "Forward
rotation speed limit/speed limit" is applied for the speed limit.
●
When the torque command becomes negative, the setting of Pr. 809 "Reverse rotation speed limit/
reverse-side speed limit" is applied to prevent the speed from increasing in the reverse rotation
direction. (The speed limit value and reverse-side speed limit value are limited at Pr. 1 "Maximum
frequency" (maximum 400 Hz under vector control).
I002818E, I002819E
Fig. 5-53:
Speed limit mode 3
Pr. 809
ON
Speed limit value
Torque command
value
Range where torque
control is available
Reverse side speed
limit value
Pr. 809
Range where torque
control is available
Range where torque
control is available
Reverse side speed
limit value
Reverse side speed
limit value
Start signal
Start signal
OFF
OFF
ON
Time
Speed limit value
Speed limit value
Pr. 809
Pr. 809
Pr. 7
Pr. 8
Pr. 8
Pr. 7
Forward
rotation
Reverse
rotation
Unwinding
(regenerative driving)
Winding
(power driving)
Unwinding
(regenerative driving)
Winding
(power driving)
Forward
rotation
Reverse
rotation
Rotation speed
Range where torque
control is available
Rotation speed
Torque command
value
Reverse side speed
limit value
Pr. 809
Forward rotation
power driving
Reverse rotation
regenerative drive
Rotation speed
Time
Speed limit value
Reverse side speed
limit value
Rotation speed
For forward rotation command
For reverse rotation command
For power driving
by forward rotation command (winding)
For regenerative driving
by reverse rotation command (unwinding)
Speed limit value
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......