Parameters
Position control under vector control and PM sensorless vector control
FR-A800
5 - 161
Positioning operation by point tables, example 1 (automatic continuous positioning
operation)
The figure below shows an operation example when the following settings are made for point tables.
Positioning operation by point tables, example 2 (variable speed operation)
●
The maximum frequency can be changed during positioning operation. Use as many point tables
as the number of maximum speeds to be set.
●
The figure below shows an operation example when the following settings are made for point
tables.
Point table
Target position
Maximum
speed (Hz)
Acceleration
time (s)
Decelera-
tion time (s)
Dwell time
(ms)
Auxiliary function
Upper
Lower
1
100
0
60
5
5
1000
1 (absolute position,
continuous)
2
50
0
30
6
6
0
10 (incremental
position, individual)
Tab. 5-55:
Settings for point tables
I002536E
Fig. 5-61:
Positioning operation by point tables
NOTES
During continuous operation, the operation moves on to the next table after the position com-
mand speed becomes 0.
During continuous operation, no point table selection signal is received. Select the position feed
length by point tables before turning ON the start command. Only the maximum frequency can
be changed during operation. Position feed length cannot be switched.
Point table
Target position
Maximum
speed (Hz)
Acceleration
time (s)
Decelera-
tion time (s)
Dwell time
(ms)
Auxiliary function
Upper
Lower
1
5
0
30
1
1
0
1 (absolute position,
continuous)
2
3
0
20
Invalid
Invalid
0
11 (incremental
position, individual)
3
10
0
10
Invalid
Invalid
0
1 (absolute position,
continuous)
4
6
0
5
Invalid
Invalid
0
10 (incremental
position, individual)
Tab. 5-56:
Settings for point tables
0
STF
RH
1000000
500000
(LX)
Position command
speed
Target position
Servo ON
Point table 1
60 Hz (Pr. 4)
5 s
(Pr. 1222)
5 s
(Pr. 1223)
Pr. 1226
6 s
Dwell time (Pr. 1224)
6 s
Pr. 1227
Time
ON
ON
ON
Point table 2
30 Hz (Pr. 5)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......