Position control under vector control and PM sensorless vector control
Parameters
5 - 176
Cumulative pulse storage
●
The cumulative pulse monitor value can be retained when the power is turned OFF or the inverter
is reset.
Pr. 638
Cumulative pulse monitor
Cumulative pulse monitor
(control terminal option)
At power-OFF
At reset
At power-OFF
At reset
0
Not stored in the EEPROM
Cleared
Not stored in the EEPROM
Cleared
1
Stored in the EEPROM
Retained
Not stored in the EEPROM
Cleared
2
Not stored in the EEPROM
Cleared
Stored in the EEPROM
Retained
3
Stored in the EEPROM
Retained
Stored in the EEPROM
Retained
Tab. 5-67:
Pr. 638 settings
NOTES
When the power is turned OFF during the reset process, the cumulative pulse monitor value and
the cumulative pulse carrying overflow times are not stored in the EEPROM.
For storing the cumulative pulse monitor value and the cumulative pulse overflow times, in the
EEPROM at power OFF, connect R1/L11 with P/+, and S1/L21 with N/- so that the control power is
retained. When connecting the high power factor converter (FR-HC2) or the converter unit
(FR-CC2), assign the instantaneous power failure detection (X11) signal to an input terminal to
input the IPF signal from the FR-HC2/FR-CC2 to the terminal for X11 signal.
Parameters referred to
Pr. 52
Operation panel main monitor selection
=>
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......