(A) Application parameters
Parameters
5 - 500
5.14.7
Swinging suppression control
When an object is moved by a gantry crane, swinging is suppressed on the crane's traveling axis.
Swinging suppression control operation (Pr. 1073)
●
Setting Pr. 1073 "Swinging suppression control operation selection" = "1" enables swinging
suppression control. (Swinging suppression control is not available under zero speed or servo lock
control.)
●
During operation under swinging suppression control, the travel distance becomes longer. Input
a stop command earlier to avoid a collision with an obstacle.
●
Deceleration stop without swinging suppression control is applied for stopping as a result of PU
stop, an emergency stop command input from a communication option, Pr. 875 "Fault definition",
or an emergency stop input (X92).
Pr.
Name
Initial
value
Setting range Description
1072
A310
DC brake judgment time
for swinging suppression
control operation
3 s
0 to 10 s
Set the waiting time to start the DC injection brake
(zero speed control, servo lock) after the output
frequency reaches the Pr. 10 "DC injection brake
operation frequency" or lower.
1073
A311
Swinging suppression
control operation selection
0
0
Swinging suppression control disabled
1
Swinging suppression control enabled
1074
A312
Swinging suppression
frequency
1 Hz
0.05 to 3 Hz
Sets the swinging frequency of the load.
999
A swinging frequency is estimated based on the
Pr. 1077 to Pr. 1079 settings, and swinging
suppression control is performed.
1075
A313
Swinging suppression
depth
0
0 to 3
0 (Deep)
➔
3 (Shallow)
1076
A314
Swinging suppression
width
0
0 to 3
0 (Narrow)
➔
3 (Wide)
1077
A315
Rope length
1 m
0.1 to 50 m
Set the rope length of the crane.
1078
A316
Trolley weight
1 kg
1 to 50000 kg
Set the weight of the trolley.
1079
A317
Load weight
1 kg
1 to 50000 kg
Set the weight of the load.
I002839E
Fig. 5-240:
Timing diagram of swinging suppression
NOTES
Under torque control or position control, the swinging suppression control is disabled.
During operation of the power failure time deceleration-to-stop function, or when the automatic
restart after instantaneous power failure is enabled (Pr. 57
≠
"9999"), the swinging suppression
control is disabled.
RL
RM
STF
Frequency
Frequency command of swinging
suppression control
Time
Frequency command
ON
ON
ON
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......