Introduction
Component names
FR-A800
1 - 5
Symbol
Name
Description
Refer to
page
PU connector
Connects the operation panel or the parameter unit . This
connector also enables the RS-485 communication.
USB A connector
Connects a USB memory device.
USB mini B connector
Connects a personal computer and enables
communication with FR Configurator2.
RS-485 terminals
Enables RS-485, MODBUS RTU communication.
Terminating resistor selection switch
(SW1)
Select whether or not to use the terminating resistor for
RS-485 communication.
Plug-in option connector1
Connects a plug-in option or a communication option.
Instruction
Manual of
the option
Plug-in option connector2
!
Plug-in option connector3
"
Voltage/current input switch (SW2)
Selects between voltage and current for the terminal 2
and 4 inputs.
Control circuit terminal block
Connects cables for the control circuit.
EMC filter ON/OFF connector
Turns ON/OFF the EMC filter.
Main circuit terminal block
Connects cables for the main circuit.
Charge lamp
Stays ON while the power is supplied to the main circuit.
Wiring cover
This cover is removable without unplugging cables.
(FR-A820-01250(22K) or lower,
FR-A840-00620(22K) or lower)
Alarm lamp
Turns ON when the protective function of the inverter is
activated.
Power lamp
Stays ON while the power is supplied to the control circuit
(R1/L11, S1/L21).
Front cover (upper side)
Remove this cover for the installation of the product,
installation of a plug-in (communication) option, RS-485
terminal wiring, switching of the voltage/current input
switch, etc.
Front cover (lower side)
Remove this cover for wiring.
Operation panel (FR-DU08)
Operates and monitors the inverter.
Cooling fan
Cools the inverter.
(FR-A820-00105(1.5K) or higher,
FR-A840-00083(2.2K) or higher)
Switches for manufacturer setting
(SW3 and SW4)
Do not change the initial setting (OFF
)
—
Tab. 1-4:
Inverter component names from fig. 1-2
OFF
ON
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......