(A) Application parameters
Parameters
5 - 568
Restart at every start (Pr. 162 = "10 to 13")
When "10 to 13" is set in Pr. 162, a restart operation is performed at each start and automatic restart af-
ter instantaneous power failure (Pr. 57 start after the reset time has elapsed). When "0 (initial value) to
3" is set in Pr. 162, a restart operation is performed at the first start after a power-ON, and from the sec-
ond power-ON onwards, a start from the starting frequency is performed.
Automatic restart operation of MRS (X10) signal
The restart operation after restoration from output shutoff by the MRS (X10) signal is as shown in the
table below according to the Pr. 30 setting.
NOTES
If "2, 12" are set to Pr. 162 when encoder feedback control is invalid, the automatic restart is with a
frequency search (Pr. 162 = "0, 10").
In vector control, encoder detection frequency search is used regardless of the Pr. 162 setting. The
Pr. 58 and Pr. 299 settings are invalid at this time.
For the encoder feedback control, refer to page 5-692.
Pr. 30 setting
Operation after restoration from output shutoff by the MRS (X10) signal
2, 10, 11, 102, 110, 111
Restart operation (starting from the coasting speed)
Other than the above
Starting from Pr.13 Starting frequency.
Tab. 5-244:
Operation selection after output shutoff
NOTES
When output is shut off using safety stop function (terminals S1 and S2), the inverter restarts in the
same way as when output is shut off by MRS (X10) signal.
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......