(D) Operation command and frequency command
Parameters
5 - 264
Operation mode basics
●
The operation mode specifies the source of the start command and the frequency command for
the inverter.
●
Basically, there are following operation modes.
External operation mode
: For inputting a start command and a frequency command with an
external potentiometer and switches which are connected to the control circuit terminal.
PU operation mode
: For inputting a start command and a frequency command with the opera-
tion panel, parameter unit, or the RS-485 communication via PU connector.
Network operation mode (NET operation mode)
: For inputting a start command and a frequen-
cy command using the RS-485 terminals or communication option.
●
The operation mode can be selected from the operation panel or with the communication
instruction code.
I002570E
Fig. 5-107:
Operation modes of the inverter
NOTES
There are two settings of "3" and "4" with PU/External combined operation. The startup method
differs according to the setting value.
In the initial setting, the stop function (PU stop selection) by the operation panel or the parameter
unit
is effective in modes other than the PU operation mode. (Refer to Pr. 75 "Reset selec-
tion/disconnected PU detection/PU stop selection" on page 5-192.)
1
2
3
4
5 6
7
8
9
10
Network operation
mode
Personal computer
Programmable controller
PU operation mode
Inverter
RS-485
terminals
PU connector
PU operation mode
Network operation mode
External operation mode
USB
connector
Personal computer
Operation panel
Personal computer
Programmable controller
Personal computer
Potentiometer
Switch
Commu-
nication
option
External terminal
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......