Parameters
Control method
FR-A800
5 - 67
5.2.3
Selecting the Advanced magnetic flux vector control
Advanced magnetic flux vector control
NOTE
To use the Advanced magnetic flux vector control, set the motor capacity, the number of motor
poles, and the motor type using Pr. 80 and Pr. 81.
Fig. 5-6:
Advanced magnetic flux vector control
Magnetic flux
Magnetic flux
Magnetic flux
Perform secure wiring. (Refer to page 2-21.)
Make the motor setting. (Pr. 71)
Set the operation command. (Refer to page 5-263.)
As required
앫
Perform offline auto tuning. (Pr. 96) (Refer to page 5-67.)
앫
Select the online auto tuning. (Pr. 95) (Refer to page 5-465.)
Select the start command and speed command.
Setting the motor capacity and the number of motor poles.
(Pr. 80, Pr. 81) (Refer to page 5-56.)
Set the motor capacity (kW) in Pr. 80 "Motor capacity", and set the
number of motor poles in Pr. 81 "Number of motor poles".
(V/F control is performed when the setting is "9999" (initial value).)
Motor
Pr. 71 setting
Remarks
Mitsubishi standard motor
Mitsubishi high-efficiency motor
SF-JR
0 (initial value) (3, 4)
SF-JR 4P 1.5 kW or
lower
20
SF-HR
40
Others
0 (3)
Offline auto tuning is
required.
Mitsubishi
constant-torque motor
SF-JRCA 4P
1
SF-HRCA
50
Other (SF-JRC, etc.)
1 (13)
Offline auto tuning is
required.
Mitsubishi high performance
energy-saving motor
SF-PR
70
Other manufacturer's
standard motor
⎯
0 (3)
Offline auto tuning is
required.
Other manufacturer's constant-
torque motor
⎯
1 (13)
Offline auto tuning is
required.
For the other setting values of Pr. 71, refer to page 5-434.
For offline auto tuning, refer to page 5-440.
Set the rated motor voltage and frequency. (Pr. 83, Pr. 84)
(Refer to page 5-67.)
Set the rated motor voltage (V) in Pr. 83 "Rated motor voltage", and
set the rated motor frequency (Hz) in Pr. 84 "Rated motor frequency".
Set the motor overheat protection. (Pr. 9) (Refer to page 5-292)
Set the rated motor current (A) in Pr. 9 "Electronic thermal O/L relay".
Test run
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......