background image

Model • Modèle 

For service, contact your nearest

service depot or call:

1-800-26- 

Danby

(1-800-263-2629)

Pour obtenir le service, consultez

votre succursale régionale de

service ou téléphonez:

1-800-26- 

Danby

(1-800-263-2629)

Room Air Conditioner

The model number of your room air conditioner is found on the serial
plate located on the right side of the unit above the power cord.

All repair parts are available for purchase or special order when you
visit your nearest service depot.  To request service and/or the
location of the service depot nearest you, call the TOLL FREE
NUMBER: 

1-800-263-2629

When requesting service or ordering parts, always provide the
following information:

• Product Type
• Model Number
• Part Number
• Part Description

Climatiseur de pièce

Le numéro de modèle de votre climatiseur se trouve sur la plaque
d'information qui se trouve sur le coté droit de l’appareil par dessus le
cordon d’alimentation.

Toutes les pièces de rechange ou commandes spéciales sont
disponibles de votre centre régional de service autorisé.  Pour exiger
le service et-ou le nom de votre centre de service régional, signalez le
NUMÉRO SANS FRAIS: 

1-800-263-2629

Ayez les renseignements suivants à la portée de la main lors de la
commande de pièce ou service:

• Genre de produit
• Numéro de modèle
• Numéro de pièce
• Description de la pièce

Danby Products Limited, Guelph, Ontario Canada  N1H 6Z9

USE AND CARE

MANUAL
MANUEL

D'UTILISATION

Models • Modèles 

CAUTION:
Read and Follow All Safety Rules
and Operating Instructions Before
First Use of This Product.

PRÉCAUTION:

Veuillez lire attentivement 
les consignes de sécurité et les
instructions d'utilisation avant
l'utilisation initiale de 
ce produit.

Room Air Conditioner

Table of contents  . . . . . . . . . . . . . . . . . . . . . . . 1

Climatiseur de pièce

Table of contents  . . . . . . . . . . . . . . . . . . . . . . . 12

Danby Products Limited, Guelph, Ontario Canada  N1H 6Z9

Version 1C.2.06

                

45839-0669

Danby Products Inc., Findlay, Ohio USA  

 

Danby Products Inc., Findlay, Ohio USA  

45839-0669

DAC60 7EE

0

DAC60 7EE

0

Summary of Contents for DAC6007EE

Page 1: ...ct PR CAUTION Veuillez lire attentivement les consignes de s curit et les instructions d utilisation avant l utilisation initiale de ce produit Room Air Conditioner Table of contents 1 Climatiseur de...

Page 2: ...Only operation Cabinet Exterior Air Inlet Interior Air Outlet Control Panel NOTE Specifications are subject to change without notice for further improvement Specifications Voltage Cooling Capacity Bt...

Page 3: ...ormation will be needed when you contact a Customer Service Representative Model Number Serial Number ___________________________________________________ Date of Purchase _____________________________...

Page 4: ...g wall outlet If you are not sure whether your wall outlet is properly grounded please consult a qualified electrician 5 The wall outlet 3 pin must match the plug 3 pin on the service cord supplied wi...

Page 5: ...er is designed to be highly efficient in energy savings Follow these recommendations for greater efficiency 1 Select thermostat setting that suits your comfort needs and leave thermostat at that chose...

Page 6: ...ide a building Keep unit as far away as possible from obstacles obstructions and at least 30 76 2 cm above the floor or ground Curtains and other objects within a room should be prevented from blockin...

Page 7: ...d on the recessed portion of the window frame Pull the window down until it rests just behind the front flange of the top L shaped mounting bracket See Fig 5 Expand the shutter frames fully on each si...

Page 8: ...lter has been cleaned and replaced depress the Check Filter button in order to resume operation SLEEP MODE When activated the current set temperature is gradually increased over a one 1 hour period th...

Page 9: ...on off 12 Restore remote control default settings To operate the hand held remote control will require two AAA Alkaline batteries included Batteries should be replaced when a No signal beep is heard w...

Page 10: ...t 2 Wash the filter in lukewarm water below 40 C 104 F To get better results wash with soapy water or a neutral cleaning agent 3 Rinse the filter with clean water and dry thoroughly before re installi...

Page 11: ...ovide additional support to unit Odors Formation of mold mildew or Clean unit thoroughly algae on wet surfaces Place algaecide tablet in base pan Water dripping outside Hot and humid weather Condensat...

Page 12: ...tees express or implied made or intended by Danby Products Limited or its authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions...

Page 13: ...e or ordering parts always provide the following information Product Type Model Number Part Number Part Description Climatiseur de pi ce Le num ro de mod le de votre climatiseur se trouve sur la plaqu...

Reviews: