(C) Motor constant parameters
Parameters
5 - 434
5.13
(C) Motor constant parameters
5.13.1 Applied
motor
By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay is set according to the
used motor.
If the Advanced magnetic flux vector control, Real sensorless vector control, vector control or PM sen-
sorless vector control is selected, the motor constant necessary for control (SF-PR, SF-JR, SF-HR, SF-JR-
CA, SF-HRCA, SF-V5RU (1500 r/min series), MM-CF, etc.) is also selected at the same time.
Purpose
Parameter to set
Refer to
page
To select the motor to be used
Applicable motor
P.C100, P.C200
Pr. 71, Pr. 450
To run by maximizing the performance
of the induction and vector motors
Offline auto tuning
P.C000, P.C100 to
P.C105, P.C107,
P.C108, P.C110,
P.C120 to P.C126,
P.C200 to P.C205,
P.C207, P.C208,
P.C210, P.C220 to
P.C226
Pr. 9, Pr. 51, Pr. 71,
Pr. 80 to Pr. 84,
Pr. 90 to Pr. 94, Pr. 96,
Pr. 453 to Pr. 463,
Pr. 684, Pr. 707, Pr. 724,
Pr. 744, Pr. 745, Pr. 859,
Pr. 860
To run by maximizing the performance
of the PM motor
PM motor offline auto
tuning
P.C000, P.C100 to
P.C108, P.C110,
P.C120, P.C122,
P.C123, P.C126,
P.C130 to P.C133,
P.C150, P.C182,
P.C185,
P.C200 to P.C208,
P.C210, P.C220,
P.C222, P.C223,
P.C226,
P.C230 to P.C233,
P.C282, P.C285
Pr. 9, Pr. 51, Pr. 71,
Pr. 80, Pr. 81, Pr. 83,
Pr. 84, Pr. 90, Pr. 92,
Pr. 93, Pr. 96, Pr. 450,
Pr. 453, Pr. 454, Pr. 456
to Pr. 458, Pr. 460,
Pr. 461, Pr. 463, Pr. 684,
Pr. 702, Pr. 706, Pr. 707,
Pr. 711, Pr. 712, Pr. 717,
Pr. 721, Pr. 724, Pr. 725,
Pr. 738 to Pr. 747,
Pr. 788, Pr. 859, Pr. 860,
Pr. 1002
To perform high accuracy operation
without being affected by
temperature and high-torque/ultra-
low speed
Online auto tuning
P.C111, P.C211
Pr. 95, Pr. 574
To use the motor with encoder
Encoder
specifications
P.C140, P.C141,
P.C240, P.C241
Pr. 359, Pr. 369,
Pr. 851, Pr. 852
To detect signal loss of encoder signals Signal loss detection
P.C148, P.C248
Pr. 376, Pr. 855
Pr.
Name
Initial value
Setting range
Description
71
C100
Applied motor
0
0 to 6, 13 to 16, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54, 70, 73, 74,
330, 333, 334, 8090,
8093, 8094, 9090, 9093,
9094
By selecting a motor, the thermal
characteristic and motor constant
of each motor are set.
450
C200
Second applied motor
9999
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 30, 33, 34, 40, 43,
44, 50, 53, 54, 70, 73, 74,
330, 333, 334, 8090,
8093, 8094, 9090, 9093,
9094
Set it when using the second
motor.
(the same specifications as Pr. 71)
9999
The function is disabled.
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......