Parameters
(E) Environment setting parameters
FR-A800
5 - 189
5.7
(E) Environment setting parameters
Purpose
Parameter to set
Refer to
page
To set the time
Real time clock function
P.E020 to P.E022
Pr. 1006 to Pr. 1008
To set a limit for the reset function.
To shut off output if the operation panel
disconnects.
To force deceleration to a stop on the
operation panel.
Reset selection/
disconnected PU
detection/PU stop
selection/Reset limit
P.E100 to P.E102,
P.E107
Pr. 75
To select the display language of the
parameter unit
PU display language
selection
P.E103
Pr. 145
To control the buzzer of the parameter
unit and operation panel
PU buzzer control
P.E104
Pr. 990
To adjust the LCD contrast of the
parameter unit
PU contrast adjustment
P.E105
Pr. 991
To turn OFF the operation panel when
not using it for a certain period of time
Display-off mode
P.E106
Pr.1048
To use the USB memory
USB host reset
P.E110
Pr. 1049
To use the setting dial of the operation
panel like a potentiometer to set the
frequency.
To disable the operation panel.
Operation panel
operation selection
P.E200
Pr. 161
To change the frequency change
increments which changes when using
the setting dial of the operation panel
Frequency change
increment amount setting
P.E201
Pr. 295
To use the regeneration unit to increase
the motor braking torque
Regenerative brake
selection
P.E300, P.G107
Pr. 30, Pr. 70
To change the overload current rating
specification
Multiple rating setting
P.E301
Pr. 570
To input a voltage between 480 V and
500 V
Input voltage mode
selection
P.E302
Pr. 977
To prevent parameter rewriting
Parameter write disable
selection
P.E400
Pr. 77
To restrict parameters with a password
Password function
P.E410, P.E411
Pr. 296, Pr. 297
To use parameters freely
Free parameter
P.E420, P.E421
Pr. 888, Pr. 889
To change parameter settings for an IPM
motor as a batch
IPM parameter
initialization
P.E430
Pr. 998
To set multiple parameters as a batch
Automatic parameter
setting
P.E431
Pr. 999
To display the required parameters
Applicable parameter
display and user group
function
P.E440 to P.E443
Pr. 160,
Pr. 172 to Pr. 174
To release the parameter copy warning
(CP)
Parameter copy alarm
release
P.E490
Pr. 989
To reduce the motor noise and EMI
PWM carrier frequency
changing
P.E600 to P.E602
Pr. 72, Pr. 240,
Pr. 260
To understand the maintenance time of
inverter parts and peripheral device
Inverter parts life display
P.E700 to P.E704
Pr. 255 to Pr. 259
Maintenance output
function
P.E710 to P.E715
Pr. 503, Pr. 504,
Pr. 686 to Pr. 689
Current average value
monitor signal
P.E720 to P.E722
Pr. 555 to Pr. 557
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......