Copying and verifying parameters on the operation panel
Parameters
5 - 702
5.18.1 Parameter
copy
Inverter parameter settings can be copied to other inverters.
Reading the parameter settings of the inverter to the operation panel
Copying parameter settings read to the operation panel to the inverter
Operation
Connect the operation panel to the source inverter.
Parameter setting mode
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
Selecting the parameter number
Turn
to
(parameter copy), and press
.
"
" appears.
#
Reading to operation panel
Turn
to change the set value to "
". Press
to start reading of the inverter parameter settings by
the operation panel. (It takes about 30 seconds to read all the settings. During reading, "
" flickers.)
,
End reading
"
" and "
" flicker alternately after settings are read.
Tab. 5-320:
Reading the parameter settings of the inverter to the operation panel
NOTE
appears... Why?
Parameter read error. Perform the operation from step
again.
Operation
Connect the operation panel to the destination inverter.
Parameter setting mode
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
Selecting the parameter number
Turn
to
(parameter copy), and press
.
"
" appears.
#
Selecting parameter copy
Turn
to change the setting value to "
" and press
.
appears.
,
Copying to the inverter
Press
to start copying to the inverter. (It takes about 60 seconds to copy all the settings. During copying, the
selected parameter group flickers.)
Perform this step while the inverter is stopped. (Parameter settings cannot be copied during operation.)
$
Ending copying
"
" and "
" flicker alternately after copying ends.
%
When parameters are written to the destination inverter, reset the inverter before operation by, for example, turning
the power supply OFF.
Tab. 5-321:
Copying parameter settings read to the operation panel to the inverter
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......