Installation and wiring
Parameter settings for a motor with encoder
FR-A800
2 - 75
●
When using the inverter with the SF-V5RU1, SF-V5RU3, or SF-V5RU4, refer to the table below to
set Pr. 83 "Rated motor voltage" and Pr. 84 "Rated motor frequency".
Combination with the vector control dedicated motor
When using the inverter with a vector control dedicated motor, refer to the table below.
●
Combination with the SF-V5RU and SF-THY (ND rating)
Motor model
Pr. 83 setting [V]
200 V class
400 V class
Pr. 84 setting [Hz]
SF-V5RU1-30kW or lower
160
320
33.33
SF-V5RU1-37kW
170
340
SF-V5RU3-22kW or lower
160
320
SF-V5RU3-30kW
170
340
SF-V5RU4-3.7kW and 7.5kW
150
300
16.67
SF-V5RU4 and motors other
than described above
160
320
Tab. 2-40:
Rated motor voltage and rated motor frequency (when using SF-V5RU1, SF-V5RU3,
SF-V5RU4)
Voltage
200 V class
400 V class
Rated
speed
1500 r/min
Base
frequency
50 Hz
Maximum
speed
3000 r/min
Motor
capacity
Motor frame
number
Motor model
Inverter model
FR-A820-
첸
Motor frame
number
Motor model
Inverter model
FR-A840-
첸
1.5 kW
90L
SF-V5RU1K
00167(2.2K)
90L
SF-V5RUH1K
00083(2.2K)
2.2 kW
100L
SF-V5RU2K
00250(3.7K)
100L
SF-V5RUH2K
00083(2.2K)
3.7 kW
112M
SF-V5RU3K
00340(5.5K)
112M
SF-V5RUH3K
00126(3.7K)
5.5 kW
132S
SF-V5RU5K
00490(7.5K)
132S
SF-V5RUH5K
00250(7.5K)
7.5 kW
132M
SF-V5RU7K
00630(11K)
132M
SF-V5RUH7K
00310(11K)
11 kW
160M
SF-V5RU11K
00770(15K)
160M
SF-V5RUH11K
00380(15K)
15 kW
160L
SF-V5RU15K
00930(18.5K)
160L
SF-V5RUH15K
00470(18.5K)
18.5 kW
180M
SF-V5RU18K
01250(22K)
180M
SF-V5RUH18K
00620(22K)
22 kW
180M
SF-V5RU22K
01540(30K)
180M
SF-V5RUH22K
00770(30K)
30 kW
200L
SF-V5RU30K
01870(37K)
200L
SF-V5RUH30K
00930(37K)
37 kW
200L
SF-V5RU37K
02330(45K)
200L
SF-V5RUH37K
01160(45K)
45 kW
200L
SF-V5RU45K
03160(55K)
200L
SF-V5RUH45K
01800(55K)
55 kW
225S
SF-V5RU55K
03800(75K)
225S
SF-V5RUH55K
02160(75K)
75 kW
250MD
SF-THY
04750(90K)
250MD
SF-THY
02600(90K)
90 kW
⎯
⎯
⎯
250MD
SF-THY
03250(110K)
110 kW
⎯
⎯
⎯
280MD
SF-THY
03610(132K)
132 kW
⎯
⎯
⎯
280MD
SF-THY
04320(160K)
160 kW
⎯
⎯
⎯
280MD
SF-THY
04810(185K)
200 kW
⎯
⎯
⎯
280L
SF-THY
05470(220K)
250 kW
⎯
⎯
⎯
315H
SF-THY
06830(280K)
Tab. 2-41:
Combination with the SF-V5RU and SF-THY
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......