Parameter List
Parameters
5 - 20
M
o
to
r c
o
nstants
702
C106
Maximum motor frequency
0 to 400 Hz, 9999
0.01 Hz
9999
706
C130
Induced voltage constant (phi f )
0 to 5000 mV/(rad/s),
9999
0.1 mV/(rad/s)
9999
707
C107
Motor inertia (integer)
10 to 999, 9999
1
9999
711
C131
Motor Ld decay ratio
0 to 100%, 9999
0.1%
9999
712
C132
Motor Lq decay ratio
0 to 100%, 9999
0.1%
9999
717
C182
Starting resistance tuning
compensation
0 to 200%, 9999
0.1%
9999
721
C185
Starting magnetic pole position
detection pulse width
0 to 6000 μs, 10000 to
16000 μs, 9999
1 μs
9999
724
C108
Motor inertia (exponent)
0 to 7, 9999
1
9999
725
C133
Motor protection current level
100 to 500%, 9999
0.1%
9999
738
C230
Second motor induced voltage
constant (phi f )
0 to 5000 mV/(rad/s),
9999
0.1 mV/(rad/s)
9999
739
C231
Second motor Ld decay ratio
0 to 100%, 9999
0.1%
9999
740
C232
Second motor Lq decay ratio
0 to 100%, 9999
0.1%
9999
741
C282
Second starting resistance tuning
compensation
0 to 200%, 9999
0.1%
9999
742
C285
Second motor magnetic pole detection
pulse width
0 to 6000 μs, 10000 to
16000 μs, 9999
1 μs
9999
743
C206
Second motor maximum frequency
0 to 400 Hz, 9999
0.01 Hz
9999
744
C207
Second motor inertia (integer)
10 to 999, 9999
1
9999
745
C208
Second motor inertia (exponent)
0 to 7, 9999
1
9999
746
C233
Second motor protection current level
100 to 500%, 9999
0.1%
9999
⎯
747
G350
Second motor low-speed range torque
characteristic selection
0, 9999
1
9999
PID c
o
ntr
o
l
753
A650
Second PID action selection
0, 10, 11, 20, 21, 50, 51,
60, 61, 70, 71, 80, 81, 90,
91, 100, 101, 1000, 1001,
1010, 1011, 2000, 2001,
2010, 2011
1
0
754
A652
Second PID control automatic
switchover frequency
0 to 590 Hz, 9999
0.01 Hz
9999
755
A651
Second PID action set point
0 to 100%, 9999
0.01%
9999
756
A653
Second PID proportional band
0.1 to 1000%, 9999
0.1%
100%
757
A654
Second PID integral time
0.1 to 3600 s, 9999
0.1 s
1 s
758
A655
Second PID differential time
0.01 to 10 s, 9999
0.01 s
9999
759
A600
PID unit selection
0 to 43, 9999
1
9999
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (19)
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......