Parameters
Parameter List
FR-A800
5 - 7
PU c
o
nne
c
tor
co
mmunica
ti
on
117
N020
PU communication station number
0 to 31
1
0
118
N021
PU communication speed
48, 96, 192, 384, 576,
768, 1152
1
192
119
⎯
PU communication stop bit length /
data length
0, 1, 10, 11
1
1
N022
PU communication data length
0, 1
0
N023
PU communication stop bit length
0, 1
1
120
N024
PU communication parity check
0 to 2
1
2
121
N025
Number of PU communication retries
0 to 10, 9999
1
1
122
N026
PU communication check time interval
0, 0.1 to 999.8 s, 9999
0.1 s
9999
123
N027
PU communication waiting time
setting
0 to 150 ms, 9999
1
9999
124
N028
PU communication CR/LF selection
0, 1, 2
1
1
⎯
125
T022
Terminal 2 frequency setting gain
frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
⎯
126
T042
Terminal 4 frequency setting gain
frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
PID oper
a
tion
127
A612
PID control automatic switchover
frequency
0 to 590 Hz, 9999
0.01 Hz
9999
128
A610
PID action selection
0, 10, 11, 20, 21, 40 to 43,
50, 51, 60, 61, 70, 71, 80,
81, 90, 91, 100, 101,
1000, 1001, 1010, 1011,
2000, 2001, 2010, 2011
1
0
129
A613
PID proportional band
0.1 to 1000%, 9999
0.1%
100%
130
A614
PID integral time
0.1 to 3600 s, 9999
0.1 s
1 s
131
A601
PID upper limit
0 to 100%, 9999
0.1%
9999
132
A602
PID lower limit
0 to 100%, 9999
0.1%
9999
133
A611
PID action set point
0 to 100%, 9999
0.01%
9999
134
A615
PID differential time
0.01 to 10 s, 9999
0.01 s
9999
By
pas
s
135
A000
Electronic bypass sequence selection
0, 1
1
0
136
A001
MC switchover interlock time
0 to 100 s
0.1 s
1 s
137
A002
Start waiting time
0 to 100 s
0.1 s
0.5 s
138
A003
Bypass selection at a fault
0, 1
1
0
139
A004
Automatic switchover frequency from
inverter to bypass operation
0 to 60 Hz, 9999
0.01 Hz
9999
Back
lash
me
as
ur
e
s
140
F200
Backlash acceleration stopping
frequency
0 to 590 Hz
0.01 Hz
1 Hz
141
F201
Backlash acceleration stopping time
0 to 360 s
0.1 s
0.5 s
142
F202
Backlash deceleration stopping
frequency
0 to 590 Hz
0.01 Hz
1 Hz
143
F203
Backlash deceleration stopping time
0 to 360 s
0.1 s
0.5 s
⎯
144
M002
Speed setting switchover
0, 2, 4, 6, 8, 10, 12, 102,
104, 106, 108, 110, 112
1
4
PU
145
E103
PU display language selection
0 to 7
1
—
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Tab. 5-2:
Parameter overview (by number) (6)
Simple
Simple
Simple
Simple
Simple
Simple
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......