Parameters
Position control under vector control and PM sensorless vector control
FR-A800
5 - 163
Selecting the home position return method (Pr. 1282 to Pr. 1288)
Pr. 1282 Setting
Home position return
method
Description
0
Deceleration starts when the proximity dog signal is turned ON. For the home position after turn
OFF of the proximity dog signal, the position specified by the first Z-phase signal or the position of
the first Z-phase signal shifted by the home position shift amount (Pr. 1285, Pr. 1286) is used.
I002538E
1
Count type
Deceleration starts when the proximity dog signal is turned ON. After the proximity dog, the
motor travels the specified travel distance (Pr. 1287, Pr. 1288). Then, it uses the position specified
by the the first Z-phase signal or position of the Z-phase signal shifted by the home position shift
amount (Pr. 1285, Pr. 1286).
I002539E
2
Data set type
The position at which the start signal is input is used as the home position.
I002540E
Tab. 5-57:
Home position return methods (1)
Vector
Vector
Vector
X76
LX
0
STF
Home position
return speed
Point table 1
acceleration time
Point table 1
deceleration time
Creep speed
Home
position
Time
Proximity dog
Z-phase
Point table selection signal
Position command
speed
Home position
shift amount
Vector
Vector
Vector
X76
LX
0
STF
Home position
return speed
Point table 1
deceleration time
Creep speed
Proximity dog
Time
Home position
shift amount
Home
position
Z-phase
Position command
speed
Point table selection signal
Point table 1
acceleration time
Travel distance
after proximity
dog
Vector
Vector
Vector
PM
PM
PM
LX
0
STF
Home position
Time
Position command speed
Point table selection signal
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......