(E) Environment setting parameters
Parameters
5 - 206
Writing parameters during operation (Pr. 77 = "2")
●
These parameters can always be written.
●
The following parameters cannot be written during operation if Pr. 77 = "2". To change the
parameter setting value, stop the operation.
Pr.
Name
Pr.
Name
23
Stall prevention operation level
compensation factor at double speed
454
Number of second motor poles
48
Second stall prevention operation level
455
Second motor excitation current
49
Second stall prevention operation
frequency
456
Rated second motor voltage
60
Energy saving control selection
457
Rated second motor frequency
61
Reference current
458 to 462
(Second motor constant)
66
Stall prevention operation reduction
starting frequency
463
Second motor auto tuning setting/status
71
Applied motor
541
Frequency command sign selection
(CC-Link)
79
Operation mode selection
560
Second frequency search gain
80
Motor capacity
561
PTC thermistor protection level
81
Number of motor poles
570
Multiple rating setting
82
Motor excitation current
574
Second motor online auto tuning
83
Rated motor voltage
598
Undervoltage level
84
Rated motor frequency
606
Power failure stop external signal input
selection
90 to 94
(Motor constant)
639, 640
(Brake sequence)
95
Online auto tuning selection
641, 650, 651
(Second brake sequence)
96
Auto tuning setting/status
660, 661, 662
(Increased magnetic excitation
deceleration)
135 to 139
(Electronic bypass sequence parameter)
673
SF-PR slip amount adjustment operation
selection
178 to 196
(Input and output terminal function
selection)
699
Input terminal filter
248
Self power management selection
702
Maximum motor frequency
254
Main circuit power OFF waiting time
706, 707, 711,
712, 717, 721,
724, 725
(PM motor tuning)
261
Power failure stop selection
738 to 746
(Second PM motor tuning)
289
Inverter output terminal filter
747
Second motor low-speed range torque
characteristic selection
291
Pulse train I/O selection
788
Low speed range torque characteristic
selection
292
Automatic acceleration/deceleration
800
Control method selection
293
Acceleration/deceleration separate
selection
819
Easy gain tuning selection
298
Frequency search gain
858
Terminal 4 function assignment
313 to 322
(Extended output terminal function
selection)
859
Torque current/Rated PM motor current
329
Digital input unit selection
860
Second motor torque current/
Rated PM motor current
373
Resolver position tuning setting/status
862
Encoder option selection
406
High resolution analog input selection
868
Terminal 1 function assignment
414
PLC function operation selection
977
Input voltage mode selection
415
Inverter operation lock mode setting
998
PM parameter initialization
418
Extension output terminal filter
999
Automatic parameter setting
419
Position command source selection
1002
Lq tuning target current adjustment
coefficient
420, 421
(Electronic gear)
1103
Deceleration time at emergency stop
450
Second applied motor
1105
Resolver magnetic pole position offset
451
Second motor control method selection
1292
Position control terminal input selection
453
Second motor capacity
1293
Roll feeding mode selection
Tab. 5-76:
Parameters, that cannot be written during operation
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......