background image

Hager witty park XEV6xx

6LE002957D

6LE002957D

 

1

z

Installation manual

1. Initial precautions

Please refer to the maintenance manual before starting the installation of the charging station. The device is to be installed only by a professional electrician 

fitter according to local applicable installation standards. Conform to SELV installation rules.

2. General description

Strip light
RFID Card Reader

Socket: Mode 3 Type 2S

Socket: Mode 2 

Optional:

 integration of a modem

Energy meter (version-specific)

The outer casing can be removed  

by unscrewing two screws

Optional:

 base

Optional integration of a protective casing

Summary of Contents for witty park XEV6 Series

Page 1: ...e installed only by a professional electrician fitter according to local applicable installation standards Conform to SELV installation rules 2 General description Strip light RFID Card Reader Socket...

Page 2: ...ing space at the rear Contact detection fixed on the contactor Controller MID energy meter version specific Grommet plate Controller power supply Terminal blocks Plug N 3 M3T2S socket lockable Plug N...

Page 3: ...nal Installation Area 713 1472 765 480 1239 330 1089 2 0 2 2 0 2 1 7 5 355 355 1300 max 233 87 50 1395 max 435 235 8 5 54 4x not included 2x 2x 175 110 325 650 325 70 350 250 190 250 500 250 Foundatio...

Page 4: ...coder wheel to an authorised threshold Then turn on the terminal a steady green light should light up N Three phase power supply 1 X1 X2 Controller power supply MZ203 Trigger circuit connection X3 Thr...

Page 5: ...onnection c Protections Single phase Electrical cabinet Station Protection integrated in the electronic board Power 4 kVA only MZ203 transmitter coils Fault detected Information via solid red indicato...

Page 6: ...e management is done through the local configurator 10 11 c 2 OCPP configuration Enables configuration of the connection to an OCPP server to be retrieve from the CPO OCPP server OCPP server address A...

Page 7: ...hase 7A mini current for three phase 13A If the setting Zoe_ph2_kangoo_twingo 2 is set mini current for one phase 6A mini current for three phase 7A c 7 Sub metering Two MID meters are integrated in t...

Page 8: ...power load 7kW 1 phase Version 22kW 3 phases Version Class of electrical protection Class 1 Socket outlet Mode 3 T2S Domestic socket Mode 2 Overvoltage category III Mechanical characteristics Weight 3...

Page 9: ...socket and the EV plug should only be used if they have been specifically designed and approved by the vehicle manufacturer or the manufacturer of the EV power system and meet national requirements T...