Position control under vector control and PM sensorless vector control
Parameters
5 - 172
5.5.6 Pulse
monitor
Various pulses can be monitored.
The setting is available when a vector control compatible option is installed.
Pulse monitor selection (Pr. 430)
●
Shows the various pulse conditions during operation as the number of pulses.Set "0" in Pr. 52
"Operation panel main monitor selection" to display the output frequency monitor.
●
If any of "26 to 31" is set in Pr. 52, Pr. 774 to Pr. 776, and Pr. 992, the electronic gear operation setting
for the pulse monitor by the multifunction monitor can be changed. (Refer to page 5-327.)
Pr.
Name
Initial
value
Setting
range
Description
430
B011
Pulse monitor selection
9999
0 to 5, 12, 13,
100 to 105,
112, 113,
1000 to
1005, 1012,
1013, 1100
to 1105,
1112, 1113
Shows the various pulse conditions during operation
as the number of pulses.
8888, 9999
Shows the frequency monitor.
635
M610
Cumulative pulse clear
signal selection
0
0 to 3
Select the clearing method for the cumulative pulse
monitor.
636
M611
Cumulative pulse division
scaling factor
1
1 to 16384
Set the division scaling factor on the cumulative pulse
for the plug-in option (FR-A8AP).
637
M612
Control terminal option-
Cumulative pulse division
scaling factor
1
1 to 16384
Set the division scaling factor on the cumulative pulse
for the control terminal option (FR-A8TP).
638
M613
Cumulative pulse storage
0
0 to 3
Select the processing method for the cumulative
pulse monitor value when the power is turned OFF or
the inverter is reset.
Pr. 430 Setting
Description
첸첸첸
0
Pulse monitor
selection
Displays the lower of the position command (accumulated value of command
pulses).
첸첸첸
1
Displays the upper of the position command (accumulated value of command
pulses).
첸첸첸
2
Displays the lower of the current position (accumulated value of feedback
pulses
).
첸첸첸
3
Displays the upper of the current position (accumulated value of feedback
pulses
).
첸첸첸
4
Displays the lower of the accumulated value of droop pulses.
첸첸첸
5
Displays the upper of the accumulated value of droop pulses.
첸첸
12
Displays the lower of the current position 2 (accumulated value of feedback
pulses
)
첸첸
13
Displays the upper of the current position 2 (accumulated value of feedback
pulses
)
첸
0
첸첸
For pulse monitor
selection
Displays the monitor item selected in the pulse monitor selection after the
electronic gear operation.
첸
1
첸첸
Displays the monitor item selected in the pulse monitor selection before the
electronic gear operation.
Tab. 5-62:
Pulse monitor selection (1)
Vector
Vector
Vector
PM
PM
PM
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......