(M) Monitor display and monitor output signal
Parameters
5 - 382
5.11.11
Analog remote output function
An analog value can be output from the analog output terminal.
Analog remote output (Pr. 656 to Pr. 659)
●
The terminals FM/CA, AM and the analog output terminal of the option FR-A8AY can output the
values set in Pr. 656 to Pr. 659 (Analog remote output).
●
When Pr. 54 "FM/CA terminal function selection" = "87, 88, 89, or 90" (remote output), the FM type
inverter can output a pulse train from the terminal FM.
●
For FM output (Pr. 291 "Pulse train I/O selection" = "0 (initial value) or 1"):
Terminal FM output [pulses/s] = 1440 [Hz] × (analog remote output value – 1000)/100
Where the output range is 0 to 2400 pulses/s.
●
For high-speed pulse output (Pr. 291 "Pulse train I/O selection" = "10, 11, 20, or 21"):
Terminal FM output [pulses/s] = 50K [Hz] × (analog remote output value – 1000)/100
Where the output range is 0 to 55K pulses/s.
Pr.
Name
Initial
value
Setting
range
Description
655
M530
Analog remote
output selection
0
0
Remote output data is cleared when the
power supply is turned OFF
Remote output data is
cleared during an inverter
reset
1
Remote output data is retained when
the power supply is turned OFF
10
Remote output data is cleared when the
power supply is turned OFF
Remote output data is
retained during an
inverter reset
11
Remote output data is retained when
the power supply is turned OFF
656
M531
Analog remote
output 1
1000%
800 to
1200%
Value output from the terminal set as
"87" in terminal function selection
(Pr. 54, Pr. 158)
Set the analog value for
outputting from the
analog output terminals
FM/CA and AM and option
FR-A8AY.
657
M532
Analog remote
output 2
1000%
800 to
1200%
Value output from the terminal set as
"88" in terminal function selection
(Pr. 54, Pr. 158)
658
M533
Analog remote
output 3
1000%
800 to
1200%
Value output from the terminal set as
"89" in terminal function selection
(Pr. 54, Pr. 158)
659
M534
Analog remote
output 4
1000%
800 to
1200%
Value output from the terminal set as
"90" in terminal function selection
(Pr. 54, Pr. 158)
I002632E, I002633E
Fig. 5-180:
Terminal FM output
1440
1100
1200
800
1000
0
2400
50K
1100
1200
800
1000
0
55K
Pulse speed
[pulse/s]
Analog remote output value [%]
Terminal FM (FM output)
Analog remote output value [%]
Terminal FM (High-speed pulse train output)
Pulse speed
[pulse/s]
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......