Current average value monitor signal
The output current average value during constant-speed operation and the maintenance timer value
are output to the current average value monitor signal (Y93) as a pulse. The output pulse width can be
used in a device such as the I/O unit of a programmable controller as a guideline for the maintenance
time for mechanical wear, belt stretching, or deterioration of devices with age.
The pulse is repeatedly output during constant-speed operation in cycles of 20 s to the Current av-
erage monitor signal (Y93).
Initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
Initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) and higher.
I002551E
Fig. 5-80:
Monitoring the maintenance timer and current average value
Pr.
Name
Initial
value
Setting range
Description
555
E720
Current average time
1 s
0.1 to 1 s
Set the time for calculating the
average current during start pulse
output (1 s).
556
E721
Data output mask time
0 s
0 to 20 s
Set the time for not obtaining
(masking) transitional state data.
557
E722
Current average value
monitor signal output
reference current
Rated
inverter
current
0 to 500 A
Set the reference (100%) for
outputting the output current
average value signal.
0 to 3600 A
Maintenance
time
Parts have
reached their life
Input unit
Output unit
Inverter
Programmable controller
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......