background image

LZR

®

-WIDESCAN

75.0047.01 LZR-WIDESCAN Mechanical Installation 20210726 

 

Page 1 of 12

Visit website for 
available languages of 
this document.

OPENING, PRESENCE, & SAFETY SENSOR FOR INDUSTRIAL DOORS

EN

Download the 
installation app! 

MECHANICAL INSTALLATION

(MOUNTING & WIRING)

LZR-WIDESCAN  

(see next page for full diagram)

power cable (35.1554)

power cable (35.1555)

mounting screws (50.0048)

DOCUMENTS:

Mechanical Installation Guide (75.0047)

Programming Guide (75.0048)

LZR-WIDESCAN Menu Tree (78.8004)

Industrial Bracket (10INDBRACKET)

•  Phillips head screwdriver

•  LZR-WIDESCAN mobile app (not required, 

but highly recommended)

•  BEA Remote Control

Adapter Kit (10.1311)

required for use with 

Industrial Bracket and 

Mini Bracket

Mini Bracket (10MINIBRACKET)

Universal Mounting Bracket (10WBA)

WHAT'S IN THE BOX

WHAT YOU'LL NEED

OPTIONS SOLD SEPARATELY

30 ft

50 ft

Summary of Contents for BEA LZR-WIDESCAN

Page 1: ...r cable 35 1554 power cable 35 1555 mounting screws 50 0048 DOCUMENTS Mechanical Installation Guide 75 0047 Programming Guide 75 0048 LZR WIDESCAN Menu Tree 78 8004 Industrial Bracket 10INDBRACKET Phi...

Page 2: ...bracket 45 to the right 15 to the left lockable Tilt angles on bracket 10 5 Protection degree NEMA 4 IP65 Temperature range 22 140 F Norm conformity IEC 61000 6 2 IEC 61000 6 3 IEC 60950 1 IEC 60825...

Page 3: ...re to sudden and extreme temperature changes Avoid direct exposure to high pressure cleaning Avoid extreme vibrations Do not cover the sensor Do not look directly into the laser emitter or the visible...

Page 4: ...age 4 of 12 1 main connector 2 protection film 3 laser window 4 USB cap 5 LED display 6 cover 7 cover lock 8 cable passage 9 LCD screen 10 keypad 11 tilt angle adjustment screw 1 12 parallel angle adj...

Page 5: ...etooth pairing sensors 2 CHECK FOR OBSTRUCTIONS If you can t see the LZR WIDESCAN it can t see you At or above the minimum mounting height check for any obstructions such as door hardware protective p...

Page 6: ...to the wall If using a right mount position the bracket must be positioned at a 30 angle You can also install the sensor directly without using the mounting bracket see inset not recommended Verify t...

Page 7: ...e control POSITION THE DETECTION FIELD OR INSTALL Connect the wires according to door manufacturer recommendations The output functions can be configured if necessary see page 9 See Appendix page 17 f...

Page 8: ...e top of the sensor If using the app verify angle setting NOTE When the safety function is required position the red spots as close to the door as possible Negative angles reduce the maximum possible...

Page 9: ...re aligned NOTE Visible spots may no longer be centered during this step b While observing the LCD screen rotate the sensor to align the center of the red spots with the center of the door then press...

Page 10: ...lace remote if necessary Too far away from sensor Stand directly underneath the LZR WIDESCAN and point remote at bottom of LED window Red spots turned on but not visible on ground Sensor is obstructed...

Page 11: ...75 0047 01 LZR WIDESCAN Mechanical Installation 20210726 Page 11 of 12 APPENDIX...

Page 12: ...2X SHORT PRESS LONG PRESS FORMER HARNESSES COM NO NC TEST POWER OUTPUT 2 OUTPUT 1 RELAY COM NO NC TEST POWER OUTPUT 2 OUTPUT 1 RELAY Previous EU harness Previous US harness HOW TO USE THE REMOTE CONTR...

Reviews: