background image

R o o m   A i r   C o n d i t i o n e r

INSTALLATION AND
OPERATING  INSTRUCTIONS

F563463

OFF/ON

OPERATIO

N

TEMP/TIM

ER

COOL
FAN

HIGH
MED
LOW

MODE

FAN SPE

ED

SET

TIMER

SET/

CANCEL

hr

°

F

ECONOM

Y

Wireless

R e mote

  C o ntro

l

Please read these operating instructions thoroughly before using your air conditioner and keep them for future reference.
For assistance, please call: 1-800-211-PANA (7262) or send e-mail to [email protected] or refer to
www.panasonic.com

SAFETY PRECAUTIONS .................................................................................................................................... 2

AIR CONDITIONER INSTALLATION .................................................................................................................. 4

PART IDENTIFICATION .................................................................................................................................... 10

PREPARATIONS BEFORE OPERATION ......................................................................................................... 12

AIR CONDITIONER OPERATION .................................................................................................................... 13

HELPFUL INFORMATION ................................................................................................................................ 20

ENERGY SAVING HINTS .................................................................................................................................. 20

CARE AND MAINTENANCE ............................................................................................................................. 21

BEFORE CALLING FOR SERVICE .................................................................................................................. 24

PRODUCT SPECIFICATIONS .......................................................................................................................... 26

CONTENTS

Thank you for purchasing a Panasonic product

This 

Panasonic

 Room Air Conditioner has been designed for maximum energy efficiency and minimal noise while keeping your

room comfortably cool.

Gracias por comprar un producto Panasonic

Este Acondicionador  De Aire 

Panasonic

 ha sido diseñado para mantener la habitación a una temperatura comfortable con

máxima eficiencia de energia y mínimo ruido.

PRECAUCIONES DE SEGURIDAD ................................................................................................................... 2

INSTALACIÓN DEL ACONDICIONADOR DE AIRE .......................................................................................... 4

IDENTIFICACIÓN DE LOS COMPONENTES .................................................................................................. 10

PREPARACIÓN ANTES DEL FUNCIONAMIENTO .......................................................................................... 12

OPERACIÓN DEL ACONDICIONADOR DE AIRE ........................................................................................... 13

INFORMACIÓN ÚTIL ........................................................................................................................................ 20

CONSEJOS DE AHORRAMIENTO DE ENERGÍA ........................................................................................... 20

CUIDADO Y  MANTENIMIENTO ........................................................................................................................ 21

ANTES DE LLAMAR PARA MANTENIMIENTO .............................................................................................. 24

ESPECIFICACIONES DEL PRODUCTO .......................................................................................................... 26

CONTENIDO

CW-XC83YU

M o d e l

ES

P

AÑOL

 •

 ENGLISH

Panasonic

MODE

OPERATION

FAN SPEED

ECONOMY

SET/

CANCEL

TEMP/TIMER

TIMER

Summary of Contents for CW-XC83YU

Page 1: ...VICE 24 PRODUCT SPECIFICATIONS 26 CONTENTS Thank you for purchasing a Panasonic product This Panasonic RoomAir Conditioner has been designed for maximum energy efficiency and minimal noise while keepi...

Page 2: ...con las leyes y regulaciones locales Do not install the unit in places where inflammablegas fumesorsootmaybegenerated No instale la unidad cerca de lugares donde puedan ser producidos gases inflamabl...

Page 3: ...cionador de aire y quite el enchufe principal Do not remove the power plug by pulling the cord Do not use the unit for any other purpose than its intended use Do not block the air intake and outlet va...

Page 4: ...LLOS SUMININSTRADOS Type A Type B Type C Tipo A Tipo B Tipo C Type Part no Remarks Qty Tipo Parte no Comentario Cantidad A CWH55207A Wood Screw 6 Tornillo para madera B CWH55330 Tapping Screw 4 Tornil...

Page 5: ...7 16 PREPARATION OF AIR CONDITIONER CHASSIS PREPARACI N DEL CHASIS DEL ACONDICIONADOR DE AIRE 1Remove the front intake grille Quite la rejilla frontal de la toma de aire Push and release Presione y s...

Page 6: ...the top and bottom brackets Inserte los paneles expansibles en los soportes de arriba abajo Attach a panel retainer on the first fold of each expansion panel and secure panel retainers to cabinet usin...

Page 7: ...agua de condensaci n gotee dentro el caja debe ser instalada al nivel o con una muy ligera inclinaci n desde adentro hacia fuera 3Secure the cabinet using screws Fije la caja usando los tornillos Type...

Page 8: ...O DE AIRE OFF ON OPERATION TEMP TIMER COOL FAN HIGH MED LOW MODE FAN SPEED SET TIMER SET CANCEL hr F ECONOMY Wireless Remote Control Clockwise En el sentido del reloj Attach the part no CZ SF6P to the...

Page 9: ...frontal de la toma de aire es empujada hacia abajo Note The drain pan part no CWH40175 can be obtained from nearest servicenter Nota La bandeja de drenaje serie no CWH40175 puede ser obtanido en su se...

Page 10: ...e the air upwards downwards or straight out b Horizontal Airflow Direction Adjustment Side to Side The horizontal airflow direction vane is controlled by positioning the vane to discharge the air to t...

Page 11: ...to No caer ni tirar el telecontrol No poner el telecontrol donde esta expuesto a la luz del sol ni cerca de une fuente de calor OFF ON OPERATION TEMP TIMER COOL FAN HIGH MED LOW MODE FAN SPEED SET TIM...

Page 12: ...or an electric shock Aseg rese de que el enchufe est adecuadamente insertado Un enchufe flojo puede causar un incendio o una descarga el ctrica PREPARATIONS BEFORE OPERATION PRERAPACI N ANTES DEL FUN...

Page 13: ...60 F and 86 F 5 Press to increase temperature Press to decrease temperature 1 Empuja el bot n TEMP TIMER 5 o para seleccionar la temperatura de visualizaci n La temperatura puede estar arreglada desd...

Page 14: ...strumentos Remote control Telecontrol ECONOMY ECONOMY ECONOMY Recommended for electricity cost saving When economy button is pressed target temperature is shifted up 1 F this will reduce operating tim...

Page 15: ...acondicionado est en funcionamiento 1 Press theTIMER button The SET CANCEL indicator light will blink awaiting for setting 1 Empuja el bot n TIMER La luz del indicador SET CANCEL oscila significando...

Page 16: ...10 segundos 1 Press the SET CANCEL button to cancel the timer setting The temperature reading and SET CANCEL indicator light will turn off simultaneously Temperature setting will be displayed again 1...

Page 17: ...ijo en vez de parpadear 4 The display will show the remaining hour to the start of the operation if you set to turn on 3 hours from now the timer will show 2 at an hour later 4 La pantalla mostrar la...

Page 18: ...l Tablero de instrumentos Remote control Telecontrol AIR CONDITIONER OPERATION OPERACI N DEL ACONDICIONADOR DE AIRE AIR CONDITIONER OPERATION OPERACI N DEL ACONDICIONADOR DE AIRE ChangeTEMPERATURE MOD...

Page 19: ...ZADOR con el TEMPORIZADOR ACTIVADO Display Pantalla de visualizaci n Touch Control Panel Tablero de instrumentos Remote control Telecontrol SET SET CANCEL SET CANCEL hr F Timer Details Detalles del pr...

Page 20: ...t Ensure that curtains and drapes are always closed to keep out direct sunlight during cooling operation Avoid heat Evite la luz solar directa y el calor Aseg rese que cortinas est n siempre cerradas...

Page 21: ...ede ser f cilmente limpiado usando una aspiradora Para remover el filtro de aire por favor rem tase a la p gina 22 en Procedimientos de c mo quite la filtro de aire Aspire el frente del filtro y luego...

Page 22: ...da para operar el acondicionador de aire Desperdiciado AIR FILTER REMOVAL PROCEDURES In order to clean the air filter just lift up the front intake grille until it is supported by the stopper Tilt up...

Page 23: ...nfriamiento RECOMMENDED INSPECTION INSPECCI N DE RECOMENDADO Pre season Inspection Inspecci n pre estaci n COOL MODE OFF ON OPERATION TEMP TIMER SET TIMER hr C JET MODE FAN SPEED AIR SWING SET CANCEL...

Page 24: ...ot cool properly Si la unidad no enfr a correctamente If water drips from the rear of the unit Si agua gotea detr s de la unidad POSSIBLE CAUSES OFTHE ABOVE PROBLEMS POSIBLES CAUSAS DE LOS PROBLEMAS A...

Page 25: ...rt no CWH40175 obtained from your nearest servicenter La humedad es alta El agua condensada se est desbordando Para solucionar el problema monte un bandeja de drenaje opcional a la unidad serie no CWH...

Page 26: ...e Monof sico LA ELECTRICIDAD Frequency Hz 60 Frecuencia 60 Voltage V 115 Voltaje 115 Current Amps 6 6 Corriente 6 6 Input W 730 Potencia 730 EER Btu W h 10 7 EER 10 7 MOISTURE REMOVAL Pints h 1 9 DESH...

Page 27: ...ilures which are caused by products not supplied by the warrantor or failures which result from accident misuse abuse neglect mishandling misapplication faulty installation maladjustment of customer c...