Page 1: ...PH5 Series Portable Air Conditioner with Heat Pump Operating Instructions 2010 Soleus Air International PH5 S SERIES 3092402 ...

Page 2: ...air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit m...

Page 3: ...rature the air conditioner may not work properly PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose 1 Hose Adapter 1 Window Kit Adapter 1 Remote Control AAA Batteries 2 Window Kit 3 Sliding Panels Air Outlet Covers 1 Owner s Manual MODEL PH5 12R 32S PH5 13R 35S COOLING CAPACITY 12 000 BTU H 13 000 BTU H HEATING CAPACITY 12 000 BTU H 12 500 BTU H DEHUMIDIFIER CAPACITY 60 pts Day 60 pts Day POWE...

Page 4: ...unded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If test button is pr...

Page 5: ...PRODUCT DIAGRAM Casters Louvers Control Panel and LED display Air Filter Compartment and Air Intake 5 Exhaust Outlet Power Cord Wrap Remote Control and Holder Air Intake Drain Plug ...

Page 6: ...lled in sliding windows and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the...

Page 7: ...ove may differ from the unit described in this manual The above directions and images show general directions for Soleus Air hose portable air conditioners VENTING KIT INSTALLATION NOTE FOR THE PH5 THERE IS ONLY ONE EXHAUST HOSE TO INSTALL ...

Page 8: ...ng Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 and connect it to Hose Panel C1 by placing the Sliding Track Panel D over the Track Screw A on Hose Panel C2 6 The Hose Panels C1 C2 should now be connected using the Sliding Track Panel D 7 To complete the assembly tighten the wi...

Page 9: ...ROL PANEL LED CONTROL DISPLAY AUTO A C DEHUM FAN HEAT TIMER ON TIMER OFF TEMPERATURE AND TIMER INDICATOR COMPRESSOR ON OFF SLEEP MODE ON OFF BUCKET FULL 9 REMOTE RECEIVER FAN SPEED TIMER MODE TIME TEMP DECREASE POWER TIME TEMP INCREASE FAN SPEED OSCILLATION ON OFF LED CONTROL DISPLAY ...

Page 10: ...e and simultaneously to change from C to F 5 TIMER To program the Auto on timer first press the TIMER button when the unit is off Once the TIMER button is pressed the hours will blink on the display Press the or buttons to change the number to the desired hours for the unit to automatically turn on To program the unit to turn off automati cally press the TIMER button when the unit is on to set the...

Page 11: ... NOTE The unit operates at low fan speed during dehumidifier mode The unit cools room slightly during while dehumidifying Keep the windows and doors closed to aid the effectiveness of the unit as it removes moisture from the room NOTE The unit will not perform in dehumidifier mode when the room temperature is lower than 61 F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the un...

Page 12: ... temperature is low and the indoor humidity is high the air conditioner may not be able to evaporate some of the moisture fast enough When this happens the water will accumulate in an emergency condensate tank inside the unit Once the emergency condensate tank is full the unit will automatically shut off and the will appear on the control panel display To empty the condensate tank pull the drain p...

Page 13: ...MER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED SWING LOUVER OSCILLATION OPERATING THE UNIT USING THE REMOTE CONTROL 13 Remote color may differ from the image above ...

Page 14: ...fan speed displayed on the remote control 4 Temperature Setting When the unit is in Air Conditioner or Heating mode you can select your desired temperature Press the or to select your desired temperature setting The temperature on the LCD dis play on the remote control will increase or decrease accordingly Pressing the and buttons simultane ously will change the temperature select between F and C ...

Page 15: ...hly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess...

Page 16: ...r appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENT...