Parameter List
Parameters
5 - 2
5.1 Parameter
List
5.1.1
Parameter list (by number)
For simple variable-speed operation of the inverter, the initial value of the parameters may be used as
they are. Set the necessary parameters to meet the load and operational specifications. Parameter set-
ting, change and check can be made from the operation panel and the parameter unit.
NOTES
indicates simple mode parameters. Use Pr. 160 "User group read selection" to switch
between the simple mode and extended mode (initially set to extended mode).
Parameter setting may be restricted in some operating statuses. Use Pr. 77 "Parameter write selec-
tion" to change the setting.
Refer to Appendix A.3 (page A-5) for instruction codes for communication and availability of
parameter clear, all clear, and parameter copy of each parameter.
Fu
n
c
ti
o
n
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value
Refer
to page
Cu
st
o
m
e
r
setting
FM
CA
Basic func
tions
0
G000
Torque boost
0 to 30%
0.1%
1
H400
Maximum frequency
0 to 120 Hz
0.01 Hz
120 Hz
60 Hz
2
H401
Minimum frequency
0 to 120 Hz
0.01 Hz
0 Hz
3
G001
Base frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
4
D301
Multi-speed setting (high speed)
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
5
D302
Multi-speed setting (middle speed)
0 to 590 Hz
0.01 Hz
30 Hz
6
D303
Multi-speed setting (low speed)
0 to 590 Hz
0.01 Hz
10 Hz
7
F010
Acceleration time
0 to 3600 s
0.1 s
15 s
8
F011
Deceleration time
0 to 3600 s
0.1 s
15 s
9
H000
C103
Electronic thermal O/L relay
Rated motor current
0 to 500 A
0.01 A
Rated inverter
current
5-67,
0 to 3600 A
0.1 A
Tab. 5-2:
Parameter overview (by number) (1)
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Simple
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......