Motor rating
Specifications
8 - 8
IPM motor MM-CF (2000r/min series)
When the power supply voltage drops, we cannot guarantee the above output and rated speed.
When the load torque is 20% of the motor rating. The permissible load inertia moment ratio is
smaller when the load torque is larger.
Consult us if the load inertia moment ratio exceeds the above value.
This does not apply to the shaft through portion.
#
Value for MM-CF
첸
2C.
,
The value for MM-CF
첸
2B is indicated in parentheses.
$
Applicable one-rank higher inverters for the lifted low-speed range torque operation. PM sensor-
less vector control specification
Motor type MM-CF
첸
52(C)(B)
102(C)(B) 152(C)(B) 202(C)(B) 352(C)(B)
502(C)
702(C)
Applicable
inverter
FR-A820
첸
K
SLD
0.4
0.4
0.75
1.5
2.2
3.7
5.5
LD
0.4
0.4
0.75
1.5
2.2
3.7
5.5
ND (initial setting)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
HD
0.75
$
1.5
$
2.2
$
3.7
$
5.5
$
7.5
$
11
$
Continuous
characteristics
Rated output [kW]
0.5
1.0
1.5
2.0
3.5
5.0
7.0
Rated torque [Nm]
2.39
4.78
7.16
9.55
16.70
23.86
33.41
Rated speed
[r/min]
2000
Max. speed [r/min]
3000
Instantaneous permissible speed [r/min]
3450
Maximum torque [Nm]
4.78
9.56
14.32
19.09
33.41
47.73
66.82
Inertia moment J
,
[×10
-4
kg × m
2
]
6.6
(7.0)
13.7
(14.9)
20.0
(21.2)
45.5
(48.9)
85.6
(89.0)
120.0
160.0
Recommended ratio of load inertia
moment to motor shaft inertia moment
100 times max.
50 times max.
Rated current [A]
1.81
3.70
5.22
7.70
12.5
20.5
27.0
Insulation rank
Class F
Structure
Totally-enclosed, self-cooling (protective system: IP44
, IP65
#
)
Surrounding air temperature, humidity
-10 °C to +40 °C (non-freezing), 90% RH or less (non-condensing)
Storage temperature and humidity
-20 °C to +70 °C (non-freezing), 90% RH or less (non-condensing)
Ambience
Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist,
dust and dirt
Altitude
Max. 1000 m above sea level
Vibration
X: 9.8 m/s
2
, Y: 24.5 m/s
2
Mass [kg]
,
5.1 (7.8)
7.2 (11)
9.3 (13)
13 (20)
19 (28)
27
36
Tab. 8-7:
Motor rating MM-CF
Summary of Contents for FR-A800
Page 2: ......
Page 4: ......
Page 22: ...Contents XVIII ...
Page 30: ...Related manuals Introduction 1 8 ...
Page 122: ...Connection of stand alone option units Installation and wiring 2 92 ...
Page 180: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 934: ...Check first when you have a trouble Protective functions 6 46 ...
Page 1031: ...Appendix EC Declarations of Conformity FR A800 A 47 ...
Page 1032: ...EC Declarations of Conformity Appendix A 48 ...
Page 1033: ...Appendix EC Declarations of Conformity FR A800 A 49 ...
Page 1034: ...EC Declarations of Conformity Appendix A 50 ...
Page 1035: ...Appendix EC Declarations of Conformity FR A800 A 51 A 5 2 EMC Directive ...
Page 1036: ...EC Declarations of Conformity Appendix A 52 ...
Page 1037: ...Appendix EC Declarations of Conformity FR A800 A 53 ...
Page 1038: ...EC Declarations of Conformity Appendix A 54 ...
Page 1039: ...Appendix EC Declarations of Conformity FR A800 A 55 ...
Page 1040: ...EC Declarations of Conformity Appendix A 56 ...
Page 1041: ......