interface
Configure the primary, secondary, and control-vlan interfaces.
S6000
Syntax
interface {primary
interface
secondary
interface
control-vlan
vlan-id
}
To return to the default, use the
no interface {primary
interface
secondary
interface
control-vlan vlan-id}
command.
Parameters
primary
interface
Enter the keyword
primary
to configure the primary
interface then one of the following interfaces and slot/port
information:
•
Fast Ethernet interface
: enter the keyword
FastEthernet
then the slot/port information.
•
Port Channel interface
: enter the keyword
port-
channel
then a number. The range is from 1 to 128.
•
10-Gigabit Ethernet interface
: enter the keyword
TenGigabitEthernet
then the slot/port information
•
40-Gigabit Ethernet interface
: enter the keyword
fortyGigE
then the slot/port information
secondary
interface
Enter the keyword
secondary
to configure the secondary
interface then one of the following interfaces and slot/port
information:
•
Fast Ethernet interface
: enter the keyword
FastEthernet
then the slot/port information.
•
Port Channel interface
: enter the keyword
port-
channel
then a number. The range is from 1 to 128.
•
10-Gigabit Ethernet interface
: enter the keyword
TenGigabitEthernet
then the slot/port information
•
40-Gigabit Ethernet interface
: enter the keyword
fortyGigE
then the slot/port information
control-vlan
vlan-id
Enter the keyword
control-vlan
then the VLAN ID. The
range is from 1 to 4094.
Defaults
none
Command
Modes
CONFIGURATION (conf-frrp)
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
584
Force10 Resilient Ring Protocol (FRRP)
Summary of Contents for Networking S6000 System
Page 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Page 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Page 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Page 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Page 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...