of ACL logs is terminated with the
seq
,
permit
, or
deny
commands. The threshold range is from 1 to 100.
interval
minutes
(OPTIONAL) Enter the keyword
interval
followed by the
time period in minutes at which ACL logs must be generated.
The interval range is from 1 to 10 minutes.
monitor
(OPTIONAL) Enter the keyword
monitor
when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is five minutes. By default,
flow-based monitoring is not enabled.
Command
Modes
ACCESS-LIST
Command
History
Version 9.3.0.0
Added support for logging of ACLs on the S4810, S4820T,
and Z9000 platforms.
Version 9.4(0.0)
Added support for flow-based monitoring on the S4810,
S4820T, S6000, and Z9000 platforms.
Usage
Information
When the configured maximum threshold is exceeded, generation of logs is
stopped. When the interval at which ACL logs are configured to be recorded
expires, the subsequent, fresh interval timer is started and the packet count for that
new interval commences from zero. If ACL logging was stopped previously
because the configured threshold is exceeded, it is re-enabled for this new interval.
If ACL logging is stopped because the configured threshold is exceeded, it is re-
enabled after the logging interval period elapses. ACL logging is supported for
standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You can configure
ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable
logging for ACLs that are associated with egress interfaces.
You can activate flow-based monitoring for a monitoring session by entering the
flow-based enable
command in the Monitor Session mode. When you enable
this capability, traffic with particular flows that are traversing through the ingress
and egress interfaces are examined and, appropriate ACLs can be applied in both
the ingress and egress direction. Flow-based monitoring conserves bandwidth by
monitoring only specified traffic instead all traffic on the interface. This feature is
particularly useful when looking for malicious traffic. It is available for Layer 2 and
Layer 3 ingress and egress traffic. You may specify traffic using standard or
extended access-lists. This mechanism copies all incoming or outgoing packets on
one port and forwards (mirrors) them to another port. The source port is the
monitored port (MD) and the destination port is the monitoring port (MG).
Related
Commands
– assigns a permit filter for IP packets.
290
Access Control Lists (ACL)
Summary of Contents for Networking S6000 System
Page 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Page 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Page 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Page 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...