Version 8.3.11.4
The
brief
parameter no longer displays the current Reload
mode. To display Reload mode, use the
show reload-type
command. Modified the
show system stack-unit
command output to support Piece Part ID (PPID).
Version 8.3.11.1
Introduced on the Z9000.
Version 8.3.7.0
Introduced on the S4810.
Version 7.8.1.0
The Boot Flash field displays the code level for boot code
2.8.1.1 and newer, while older boot codes display as
"Present".
Version 7.7.1.0
Added Master Priority field.
Version 7.6.1.0
Introduced on the S-Series.
Example (show
system stack
unit – disabled
ports)
Dell#show system stack-unit 0 disabled-ports
Disabled ports in stack-unit 0
Disabled
52
56
60
Example (show
system brief)
Dell#show system brief
Stack MAC : 90:b1:1c:f4:9b:79
Reload-Type : normal-reload [Next boot :
normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp
CurTyp Version Ports
---------------------------------------------------------------
---------------------
0 Management online S6000
S6000 9-4(0-168) 128
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------
------------
0 0 down UNKNOWN down 0
0 1 up AC up 6600
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
---------------------------------------------------------------
---------------------
0 0 up up 7072 up 7072
0 1 up up 7021 up 7072
0 2 up up 7021 up 7021
Speed in RPM
Control and Monitoring
133
Summary of Contents for Networking S6000 System
Page 1: ...Dell Command Line Reference Guide for the S6000 System 9 5 0 0 ...
Page 558: ...Version 8 3 10 0 Introduced on the S4810 558 Equal Cost Multi Path ECMP ...
Page 579: ...Version 8 3 12 0 Introduced on the S4810 FCoE Transit 579 ...
Page 1331: ...Gi 3 40 configured rate 16384 actual rate 16384 sub sampling rate 1 Dell sFlow 1331 ...
Page 1480: ...Version 8 3 8 0 Introduced on the S4810 1480 Virtual Link Trunking VLT ...