Rev. 1.0, 02/00, page 745 of 1141
[Legend]
SEPH
Noise detection
window
Noise mask for
OSCH
OSCH
Noise mask for
H counter
H reload
counter
H counter
SEPH
c
OSCH
: Horizontal sync signal after detection
: Horizontal sync signal after complement
a
b
: Value set for the noise detection window (NWR5 to NWR0)
: Value set for the pulse width of the horizontal sync signal (NPWR3 to NPWR0)
c
a, b, c
: Value set for complement timing (HRTR7 to HRTR0)
: Complements of 1 of a,b,c, respectively
H ' E 8
TH
:Complement of 2 of multiplier 24 in the equation for the noise mask period
(The noise mask period ends 24 counts before the overflow of H reload counter.)
: Cycle of the horizontal sync signal
(NTSC:63.6 [ms], PAL:64[ms])
TM : Timing at which the noise mask period ends.
A horizontal sync
pulse is missing
The pulse in the mask
period is ignored
TH
a
b
H'00
OVF
H'E8
c
a
Mask
period
Period determined
by NWR5 to NWR0
Mask
period
TM
Mask
period
Mask
period
Mask
period
Mask
period
Mask
period
Mask
period
TH
Don't mask
immediately
after
complement.
period deter-
mined
by a and a
Period determined
by HRTR7 to HRTR0
period determined
by c and H'E8
Period determined
by HPWR3 to HPER0
period
determined
by b
Do mask also im-
mediately after
complement.
Figure 26.75 Set Period for HRTR, HPWR, and NWR