QUICKLINK 

A Line of External Fixed

-

Port Active Hubs for ARCNET® Local Area Networks 

INSTALLATION GUIDE 

INTRODUCTION 

The QuickLink (QL) 

S

eries of external fixed port hubs provides a low cost 

method of expanding ARCNET local area networks.  These eight-port hubs 
provide the ultimate in reliability and flexibility for cabling ARCNET 
networks.  A hub allows for the addition of a segment and support for 
distributed star topologies.  The QL utilizes the same robust hub timing 
electronics found in 

the 

Contemporary Controls (CC) MODHUB series for 

modular active hubs.  This includes precision delay line timing, digitally 
controlled timers for dependable operation and reduced bit jitter.  A

lso, a 

watchdog timer is included to prevent hub lockup

 — eliminating the need 

to recycle hub power in the event of extraordinary electrical disturbance

The QL operates from low

-

voltage AC

,

 requiring a power voltage source in 

the range of 8 to 24 volts. 

Active hubs increase the robustness of ARCNET networks.  They maximize 
the distance that can be achieved on each cable segment 

⎯ 

up to 2000 feet 

(610 m) feet on coaxial segments.  They prevent interference to the network 
by squelching reflections caused by open or shorted cable segments attached 
to the hub.  Unused hub ports need not be terminated.  Active hubs allow for 
a distributed star topology, thereby minimizing the cabling required in a 
facility.  Two or more QL hubs may be cascaded. 

Summary of Contents for QL-CXS

Page 1: ...ally controlled timers for dependable operation and reduced bit jitter Also a watchdog timer is included to prevent hub lockup eliminating the need to recycle hub power in the event of extraordinary e...

Page 2: ...TY green AC Input voltage 8 24 Volts Input power 6 VA Input frequency 47 63 Hz INSTALLATION The QL was designed as a desktop unit and should be installed on a stable surface in a horizontal plane Four...

Page 3: ...a port on the QL hub The coaxial star configuration provides the longest coaxial distance and simplified troubleshooting A CXS port effectively terminates the end of a coaxial bus segment without the...

Page 4: ...th of cable cannot exceed 2000 feet If more than two NIMs are used on a network either an active or passive hub is required With passive hubs a maximum of four NIMs can be interconnected Unused ports...

Page 5: ...ct the hub to the middle of a segment since the hub port is not of the high impedance type Do not terminate the end which attaches to the hub port since a CXS port effectively terminates the end of a...

Page 6: ...he hub port The opposite segment end still requires termination if no hub connection is being made Issue the TPS incorporates built in BALUNs requiring a phase reversal of the signals from the TPB por...

Page 7: ...5024 1998 ITE Immunity Limits and Methods Manufacturer Contemporary Control Systems Inc 2431 Curtiss Street Downers Grove IL 60515 USA Authorized Representative Contemporary Controls Ltd Sovereign Cou...

Page 8: ...red product is shipped back to the purchaser or for the remainder of the original warranty period whichever is longer If a CC product fails to operate in compliance with its specification during the w...