background image

ZT

2550/ZT

2551

  

Quick

 

Start

 

1

 

What’s

 

in

 

the

 

shipping

 

package?

 

The package includes the following items: 

ICP

 

DAS,

 

ZT

2550/ZT

2551

 

Quick

 

Start

 

Guide,

 

Version

 

1.2

   

Page

 

1

 

 

 

2

 

Preparing

 

the

 

device

 

1.

 

Install the ZT Configuration Utility (v1.0.0 or later), 

CD: 

\

Napdos

\

ZigBee

\

ZT_Series

\

Utility 

http://ftp.icpdas.com/pub/cd/usbcd/napdos/zigbee/zt_series/utility

   

2.

 

Power Supply: +10 ~ +30 V

DC

 

If any of these items are missing or damaged, please contact the local distributor 
for more information. Save the shipping materials and cartons in case you want to 
ship the module in the future. 

ZT

255x

 

Device

 

CD

 

ANT

124

05

 

Release

 

Note

 

CA

0915

 

(ZT

2550)

 

/

CA

0910N (ZT

2551)

GND

 

+Vs 

Summary of Contents for ZT-2550

Page 1: ...lity v1 0 0 or later CD Napdos ZigBee ZT_Series Utility http ftp icpdas com pub cd usbcd napdos zigbee zt_series utility 2 Power Supply 10 30 VDC If any of these items are missing or damaged please co...

Page 2: ...Bee Coordinator 3 RF Channel indicates the radio frequency channel and must be set to the same channel if the module is in the same ZigBee network as other ZigBee modules Channel 0x00 0x01 0x0F Freque...

Page 3: ...12 CH 4 2425 CH 2 2417 CH 5 2430 CH 3 2422 CH6 2435 CH 4 2427 CH 7 2440 CH 5 2432 CH 8 2445 CH 6 2437 CH 9 2450 CH 7 2442 CH A 2455 CH 8 2447 CH B 2460 CH 9 2452 CH C 2465 CH 10 2457 CH D 2470 CH 11 2...

Page 4: ...meter adjustment purely personal behavior ICP DAS can not guarantee to pass CE FCC certification if adjusting this parameter nor assume any liability because of the adjustment parameters derived from...

Page 5: ...kets This parameter is used to decide the interval time of sending broadcast frame in order to prevent the network crashes Please fill in the number of ZT 2000 slaves nearby the ZigBee Coordinator Exa...

Page 6: ...ill be sent to all ZigBee slaves ZT 2551 Unicast Data will only be sent to the coordinator Eg1 When ZT 2550 ZigBee Host sends DATA_01 via broadcasting frame Both of the ZigBee slave 0x0001 and 0x0002...

Page 7: ...ame Only the ZigBee Slave 0x0001 receives DATA_01 Note Unicast type frame data will be only sent to the specific ZigBee node Eg2 When ZigBee slave 0x0001 sends 0002DATA_02 via unicast frame Only the Z...

Page 8: ...output the data MRTU_CMD_01 to serial port directly Eg2 When ZT 2570 receives data MTCP_CMD_02 from Ethernet ZT 2551 will convert protocol then output MRTU_CMD_01 to serial port Eg3 When ZT 2551 tran...

Page 9: ...re the ZT 255x RS 232 RS 485 ZBSET ZBRUN CA 0910N CA 0915 ZT 2550 ZT 2551 Windows based PC F G D D GND VS RS 485 Converter Windows based PC ZT 255x 3 Enable the power It means that the ZT 255x start u...

Page 10: ...t icon and then select the COM Port number ICP DAS ZT 2550 ZT 2551 Quick Start Guide Version 1 2 Page 10 3 After selecting the COM Port number a list of model numbers will be displayed Select the name...

Page 11: ...both are used to configure the Pan ID Node ID RF Channel RF Power Baud rate Data Format Application Mode and so the relevant parameters 6 Once the module configuration has been completed the message T...

Page 12: ...te the data transmission ICP DAS ZT 2550 ZT 2551 Quick Start Guide Version 1 2 Page 12 Method 2 Use the DCON Utility on the Host PC to search for ZT 2000 series I O modules If there any devices are fo...

Page 13: ...be obtained using the procedure outlined below and should be attached to your email a Set the DIP switch of the ZT 255x device to the ZBSET position then reboot the device Launch the ZT Configuration...

Page 14: ...is Strong Blinking 500 ms The Signal is Available Blinking 1s The Signal is Weak ZigBee Net Green LED Blinking 2s The Signal is Unstable or There is no Available The status of ZigBee communication Bl...