-TPB Twisted-Pair Bus 

Like the -CXB transceiver, a hub

-

less cabling segment is possible.  The 

-TPB transceiver allows a total of eight -TPB NIMs to share a common bus 
segment for up to 400 feet.  These types of segments can be expanded using 
the QL-TPS.  Only connect this bus segment at the end of a segment.  Do 
not connect the hub to the middle of a segment since the hub port is not of 
the high-impedance type.  Do not terminate the end which attaches to the 
hub port since a -TPS port effectively terminates the ends of a bus segment. 
Simply remove the terminator from the segment end and attach the cable 
directly to the hub port.  The opposite segment end still requires termination 
if no hub connection is being made. 

Issue: the -TPS incorporates built-in BALUNs requiring a phase reversal of 
the signals from the -TPB port.  Therefore, the use of inverting cable is 
required. 

Figure 6 

— 

A -TPB segment can be expanded using -TPS ports on a hub. 

Wiring Chart 

RJ-11 Connector 

PIN 

-TPS 

-TPB 

2

 N/C

 N/C 

LINE+ 

LINE– 

LINE– 

LINE+ 

5

 N/C

 N/C 

– 

Electromagnetic Compatibility 

The QL series complies with Class A radiated and conducted emissions as 
defined by CFR

 47

, Part 15 and EN55022.  This equipment is intended for 

use in non-residential areas. 

Warning 

This is a Class A product as defined in EN55022.  In a domestic 
environment this product may cause radio interference in which case 
the user may be required to take adequate measures. 

TD990300-0I

F

6

Summary of Contents for QL-CXS

Page 1: ...ally controlled timers for dependable operation and reduced bit jitter Also a watchdog timer is included to prevent hub lockup eliminating the need to recycle hub power in the event of extraordinary e...

Page 2: ...TY green AC Input voltage 8 24 Volts Input power 6 VA Input frequency 47 63 Hz INSTALLATION The QL was designed as a desktop unit and should be installed on a stable surface in a horizontal plane Four...

Page 3: ...a port on the QL hub The coaxial star configuration provides the longest coaxial distance and simplified troubleshooting A CXS port effectively terminates the end of a coaxial bus segment without the...

Page 4: ...th of cable cannot exceed 2000 feet If more than two NIMs are used on a network either an active or passive hub is required With passive hubs a maximum of four NIMs can be interconnected Unused ports...

Page 5: ...ct the hub to the middle of a segment since the hub port is not of the high impedance type Do not terminate the end which attaches to the hub port since a CXS port effectively terminates the end of a...

Page 6: ...he hub port The opposite segment end still requires termination if no hub connection is being made Issue the TPS incorporates built in BALUNs requiring a phase reversal of the signals from the TPB por...

Page 7: ...5024 1998 ITE Immunity Limits and Methods Manufacturer Contemporary Control Systems Inc 2431 Curtiss Street Downers Grove IL 60515 USA Authorized Representative Contemporary Controls Ltd Sovereign Cou...

Page 8: ...red product is shipped back to the purchaser or for the remainder of the original warranty period whichever is longer If a CC product fails to operate in compliance with its specification during the w...

Reviews: