DID-DS1 (DS1 DID Trunk)
Issue 5 October 2002
993
555-233-119
1018
ABORT
The test was disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk Administration’ screen
is set to ’n’. To enable the test, change the trunk administration and enter
’y’ into the ’Maintenance Test’ field.
2. Repeat the test.
1020
ABORT
The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the previously existing error.
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053
ABORT
At least one of the following errors is found on the DS1 circuit pack: 1281—
Loss of signal, 1793—Blue Alarm, 2049—Red Alarm, 2305—Yellow Alarm,
1537—Hyperactivity.
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
Table 186.
TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page