Maintenance Commands
555-233-119
166
Issue 5 October 2002
busyout data-module
Use busyout data-module to put the data module in a maintenance busy state,
even uninstalled data modules. No periodic or scheduled tests is performed on
the busied out data module or data channel until it is released and no call
processing can be executed on the data modules or over the data channels.
Warning alarms are generated (error type 18) on each maintenance object busied
out, so that INADS can access the state of the objects. The release data module
command returns the specified data module (or data channel) to operation.
On a system with the duplication option, a busyout of a Network Control Data
Channel (DATA-CHL) or a Processor Interface Port Data Channels (PI-PT) are
preserved across SPE interchanges. The data channel extension must be
released before the data channel can be brought back into service.
Output
The following example shows the output from busyout data-module 300.
Field descriptions
Action/Object
Qualifier
Qualifier Description
Logins
Default
Feature Interactions
busyout
data-module
extension
Extension number (per dial-plan)
Example:
busyout data-module 31300
init
inads
craft
nms
None
None
Port
Port address (cabinet-carrier-slot-circuit) or data channel number
Maintenance Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is
The field contains
station
extension
trunk
xxx/yyy (xxx = trunk group, yyy = member number
private CO line
P/xxx (xxx = private CO line group number)
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. See the
detailed list of the codes by test number for each MO.
busyout data-module 300 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1103 DIG-LINE 300 PASS