MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 5 October 2002
1371
555-233-119
Misframe Alarm Inquiry Test (#145)
This test is meaningless for the TN802 MAPD circuit pack.
Table 348
details the
test results.
NOTE:
The query for misframes always returns a 0 count.
Translation Update Test (#146)
The Translation Update Test sends the circuit-pack-level information to the MAPD
Interface circuit pack. Translation includes the following data administered for a
MAPD Interface circuit pack (report from display ds1 UUCSS command):
■
DS1 Link Length between two DS1 endpoints
■
Synchronization Source Control
■
All Zero Suppression
■
Framing Mode
■
Signaling Mode
■
Time Slot Number of the 697-Hz tone
■
Time Slot Number of the 700-Hz tone
Table 348.
Misframe Alarm Inquiry Test (#145) results
If Windows NT is up
on the TN802
When the switch confirms Misframe alarm:
Y
Test passes
N
Test aborts with ABORT 2000 Error Code.