Ping Test (#1379)
This test is non-destructive
This test verifies that the MedPro circuit pack can communicate to other nodes on
the LAN.
This test pings the gateway IP address as defined on the IP Interface form.
If the PING is successful, this test looks at the PING round trip delay. If a round
trip delay of greater than 4 seconds is reported, a separate error is logged.
Excessive round trip delays do not take the MedPro out of service.
Services can execute the standard PING command using the C-LAN board
address and MedPro IP address to see the actual round-trip delay. (See ping
commands).
This test is a nondestructive test. It runs due to in-line errors, during periodic and
scheduled maintenance, and on demand.
Table 304.
TEST #1379 Ping Test
Error
Code
Test
Result
Description/ Recommendation
1, 2
ABORT
Internal Error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
7
ABORT
Destination unreachable.
1. Verify that at least one destination reachable through this port is
up.
2. Repeat the test.
3. If the test still aborts, escalate the problem.
2000
ABORT
Response to the test was not received from the Media Processor
circuit pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack.
Reset the circuit pack by issuing the busyout board UUCSS and
the reset board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page