
HYB-LINE (Hybrid Line)
Issue 5 October 2002
1249
555-233-119
1004
ABORT
The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use (off-hook)
if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1,2,3
FAIL
The control channel between the processor and the port is not transmitting
properly. This port is not operable.
1. Retry the test.
2. If the failure still occurs, issue the busyout and the release busy
commands, and then retest.
3. If the failure is occurring on more than one port on the board, suspect
the board.
4. If the failure is occurring on several boards in the same carrier, escalate
the problem.
5. If the failure still occurs and appears to be isolated to one port, check all
wiring to the set and all set connections.
6. Replace the circuit pack as a last resort.
PASS
Hybrid Line Local Digital Loop Around Test passed. The control channel is
transmitting properly.
1. If complaints still exist, investigate by using other circuit pack tests, and
by examining the station, wiring, and connections.
Table 291.
TEST #58 Hybrid Line Local Digital Loop Around Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page