test board
Issue 5 October 2002
535
555-233-119
!
WARNING:
Since the “clear long” options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Feature Interactions
Destructive long tests on a Switch Node Interface (SNI) board are not allowed
unless the board has first been busied out.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test board
location
short
long
repeat
number
clear
schedule
Physical location of the board PCSS
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive test series (includes a
destructive test)
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Use the screen to schedule execution of
the command. The command is placed
in the command queue and is executed
at the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
2
Examples:
test board 01c11 l
test board 01c11 l schedule
test board 02b15 sh r 2
test board 01c08
test board 02d12 r 4
test board 02d12 c
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
nms
Test
sequence
= short;
repeat = 1
none