RANL-STA (Remote Analog Line (Station) Port)
Issue 5 October 2002
1553
555-233-119
FAIL
The terminal equipment is not connected to the circuit pack. Some
terminal equipment, such as modems, may fail even when
connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the error log. If
present, refer to “RING-GEN”.
3. Check all of the wiring between the station equipment and the
switch. Then, run the test again.
4. If the test still fails, the set may be defective. Check the set and
replace it, if necessary.
5. Some terminal equipment could fail even when it is connected
properly. If this is the case, disable the test using the change
station extension command (enter
n
into the
Test
field). Note
that this action also disables Test #35 on this port.
PASS
The station is connected properly. This test may also pass if no
terminal equipment is connected and the terminal is located very far
from the switch. User-reported troubles on this port should be
investigated by using other port tests, by examining station wiring, or
by examining the station.