DID-TRK (DID Trunk)
Issue 5 October 2002
1009
555-233-119
Port Diagnostic Test (#35)
This test checks a port’s battery feed circuitry. The battery feed circuitry is tested
for on-/off-hook detection, battery shutdown, and battery reversal (WINK)
capabilities.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 191.
TEST #35 Port Diagnostic Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
System resources required to run this test were not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 190.
TEST #33 Looparound and Conference Circuit Test — Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page