Maintenance Objects
1702
Issue 5 October 2002
2000
ABORT
Response to the test request was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any
FAIL
This test can fail due to on-board or off-board problems. Off-board problems
of concern include TDM-BUS faults and faults associated with the tone
detectors/tone generators. Clear all off-board problems before replacing the
board. Keep in mind that a TDM-BUS problem is usually the result of a
faulty board connected to the backplane or bent pins on the backplane.
1. Look for TDM-BUS errors in the error log. If present, refer to the
TDM-BUS Maintenance documentation.
2. Look for TONE-BD and/or TONE-PT errors in the error log. If present,
refer to the TONE-BD Maintenance documentation and the TONE-PT
Maintenance documentation.
3. Test the board when the faults from steps 1 and 2 are cleared. Replace
the board only if the test fails.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining
station, trunk or external wiring.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 501.
TEST #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description/ Recommendation
Continued on next page