Maintenance Objects
555-233-119
730
Issue 5 October 2002
Error Log Entries and Test to Clear Values
Notes:
a.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence.
Refer to the appropriate test description and follow the recommended procedures.
b. Error Type 1: the two ends of the ATM trunk do not agree on the ISDN call
state. Possible causes:
■
Received a DISConnect or RELease COMplete message with
cause value 52 (outgoing calls barred)
■
Received a DISConnect or RELease COMplete message with
cause value 54 (incoming calls barred)
■
Outgoing call renegotiated by the far end to another B-channel in
the absence of SETUP message glare
■
Near end attempted a call on a B-channel that the far end has
marked OOS
When running the Short Test Sequence, pay close attention to the results
of the Call State Audit Test (#257).
Table 70. ATM-BCH Error Log entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0 (
a
)
0
Any
Any
Any
test port UUCSSppp
1(
b
)
Any
None
test port UUCSSppp
18
0
busyout trunk grp/mbr
release trunk grp/mbr
129 (
c
)
None
WNG
OFF
test port UUCSSppp
130 (
d
)
test port UUCSSppp
257(
e
)
Any
Service State Audit (Test
#256)
test port UUCSSppp
513(
f
)
Any
None
WNG
OFF
test port UUCSSppp
769(
g
)
Any
Service State Audit (Test
#256)
test port UUCSSppp
1793(
h
)
Any
None
test port UUCSSppp
3073(
i
)
Any
Service State Audit (#256)
test port UUCSSppp
3585(
j
)
Any
None
none
3841(
k
)
Any
None
WNG
OFF
none
Continued on next page