test access-endpoint
Issue 5 October 2002
525
555-233-119
test access-endpoint
Use test access-endpoint to perform hardware diagnostic tests on all port
circuits that are associated with the specified access endpoint extension.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
test
access-
endpoint
extension
short
long
repeat
number
clear
schedule
Access endpoint extension (# of digits
determined by dial-plan)
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
test series (includes a destructive test)
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm (if
any) is cleared or a single test in the
sequence fails.
1
Use the screen to schedule execution of
the command. The command is placed in
the command queue and is executed at
the specified time. The information
displayed by the command is sent to the
system printer instead of the screen.
2
Examples:
test access-endpoint 25012
test access-endpoint 45002 sh
test access-endpoint 45892 l
test access-endpoint 24389 sh r 4
test access-endpoint 34899 l r 6
test access-endpoint 34912 l r 5
schedule
test access-endpoint 93483 r 2
test access-endpoint 10022 c
test access-endpoint 92349 schedule
1
If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2
See the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
nms
Test
sequence=
short;
repeat = 1
none